Axis 2N Lift1 Brief Manual Download Page 10

EN

 

 

4 = send identification by DTMF 
5 = message as specified in parameter 

977 (after confirmation according to 
parameter 976)  

6 = combine options 5 + 2  
7 = confirmation tone (after confirmation 

only) 

876 

 

End-of call 

message language

 

selection 

0

0,3,5,7 = 

 

1 = 

English (or other main language 

depending on Lift1 version) 

= English (or tones for English 

version) 

4 = 

German

 

6 = 

Polish 

8 = 

Portugese 

9 = 

Dutch 

10 to 99 = 

silence

 

 

877 

 

Outgoing call 

message language 
selection 

0

99 

 

912 

 

Maximum call 

time 

15

990 s 

120 s 

Use the call-extending command to 
extend the call (DTMF 4 or *). 

  

913 

 

Login time limit 

(for automatic dialing) 

10

990 s 

60 s 

Set the maximum period of time for the 
control centre staff to answer the call 
and send confirmation, otherwise Lift1 
hangs up and dials the next number. 
Counted from the end of dialing. 

  

914 

 

Delayed call 

0

1000 s 

0 s 

Applied only if the CANCEL input is 
connected. 

  

916

 

 Cancel input 

inversion 

0-1 

0 = contact closed or voltage present at 

opened door 

1 = contact opened or voltage not 

present at opened door 

 

920 

 Alarm button 

mode 

0-2 

0 = normally open contact or voltage 

present to activate 

1 = normally closed contact or voltage 

not present to activate 

2 = autodetection, during the next boot 

of the device the state of the input 
will be set as not active state.  

 

962 

 

Minimum 

button pressing time 

100

9999 

ms 

100 ms 

Applies to the ALARM button. 

  

965 

 

Private mode 

0

25 

Incoming call permitted always during 
rescue process. Parameter specifies 
functionality when the rescue process 
is not active: 

 incoming call permited during 

rescue process only. 

 24 

 time after alarm, when 

incoming call is permitted (hours) 

25 

 incoming call is always enabled  

  

966 

 Rescue process 

0-4 

0 = disabled 
1 = End of rescue process by Alarm 2 
2 = End the rescue process by rescue 

password 

 

Summary of Contents for 2N Lift1

Page 1: ...EN 2N Lift1 Comunicator for Lifts Brief Manual Issue 2 Version 1 3 www 2n cz...

Page 2: ...can be delivered separately with cables to be mounted anywhere on the lift panel according the design cable version Model with the cover panel includes the front visible cover this cover overlaps bord...

Page 3: ...ic feedback between the speaker and microphone In front of the microphone must be the hole in the panel recommended diameter is 2 mm or appropriate perforation When the LED indicators on the device ar...

Page 4: ...nal speaker induction loop VAS Alarm programming connector and the board with electronics are connected to a telephone line where life endangering voltage may occur Connected switches LEDs and other p...

Page 5: ...to activate the recovery mode for FW upgrade whenever a problem occurs with the Lift1 2N Service Tool connection Switch contact The switches are used for variable purposes and are remotely DTMF contro...

Page 6: ...external microphone and speaker can be used for connecting of these parts on cables allowing the user to place it according the construction of the lift cabin These parts are delivered with the cable...

Page 7: ...n the device is first time switched on the input has to be in not active alarm state Make sure that the DoorOpen signal is only activated when both the internal and external lift doors are open and th...

Page 8: ...meter number value The parameter number has three digits see the table After you enter the number and an asterisk Lift1 shall report the number name current value and potential range of the parameter...

Page 9: ...hout confirmation 4 CPC Antenna support 5 CPC Kone support 6 P100 support 112 116 Automatic dialling type for ALARM button memories 2 6 1 6 1 171 Automatic dialing type for check call memory 1 1 6 1 1...

Page 10: ...end of dialing 914 Delayed call 0 1000 s 0 s Applied only if the CANCEL input is connected 916 Cancel input inversion 0 1 0 0 contact closed or voltage present at opened door 1 contact opened or volt...

Page 11: ...00 00 00 23 59 59 beginning and end beg 00 00 0 0 end 23 59 5 9 Set announcements for the lower traffic lower tariff time generated at random in the set time interval 983 Check call period 0 100 days...

Page 12: ...65 x 130 x 24 mm Working temperature range 20 to 70 C Note Lift1 is certified for connection to a wired PSTN line according to the ES 023 021 requirements The product does not contain components harmf...

Reviews: