EN
9
4 = send identification by DTMF
5 = message as specified in parameter
977 (after confirmation according to
parameter 976)
6 = combine options 5 + 2
7 = confirmation tone (after confirmation
only)
876
–
End-of call
message language
selection
0
–
9
1
0,3,5,7 =
1 =
English (or other main language
depending on Lift1 version)
2
= English (or tones for English
version)
4 =
German
6 =
Polish
8 =
Portugese
9 =
Dutch
10 to 99 =
silence
877
–
Outgoing call
message language
selection
0
–
99
1
912
–
Maximum call
time
15
–
990 s
120 s
Use the call-extending command to
extend the call (DTMF 4 or *).
913
–
Login time limit
(for automatic dialing)
10
–
990 s
60 s
Set the maximum period of time for the
control centre staff to answer the call
and send confirmation, otherwise Lift1
hangs up and dials the next number.
Counted from the end of dialing.
914
–
Delayed call
0
–
1000 s
0 s
Applied only if the CANCEL input is
connected.
916
–
Cancel input
inversion
0-1
0
0 = contact closed or voltage present at
opened door
1 = contact opened or voltage not
present at opened door
920
–
Alarm button
mode
0-2
0
0 = normally open contact or voltage
present to activate
1 = normally closed contact or voltage
not present to activate
2 = autodetection, during the next boot
of the device the state of the input
will be set as not active state.
962
–
Minimum
button pressing time
100
–
9999
ms
100 ms
Applies to the ALARM button.
965
–
Private mode
0
–
25
0
Incoming call permitted always during
rescue process. Parameter specifies
functionality when the rescue process
is not active:
0
–
incoming call permited during
rescue process only.
1
–
24
–
time after alarm, when
incoming call is permitted (hours)
25
–
incoming call is always enabled
966
–
Rescue process
0-4
0
0 = disabled
1 = End of rescue process by Alarm 2
2 = End the rescue process by rescue
password