AXIS 216FD Installation Guide
Page 5
ENGLISH ENGLISH
Unit connectors
Network connector -
RJ-45 Ethernet connector. Supports Power over Ethernet. Using
shielded cables is recommended.
Power connector -
Mini DC connector. 5.1V DC, max 3.6W. See product label for
±
connection.
Audio in -
3.5mm input for a mono microphone, or a line-in mono signal (left channel is
used from a stereo signal).
Audio out -
Audio output (line level) that can be connected to a public address (PA) system
or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A
stereo connector must be used for the audio out.
I/O terminal connector -
Used in applications for e.g. motion detection, event triggering,
time lapse recording, alarm notifications, etc. It provides the interface to:
• 1 transistor output - For connecting external devices such as relays and LED:s.
Connected devices can be activated by Output buttons on the
Live View
page or
by an
Event Type
. The output will show as active (shown under
Event Configu-
ration > Port Status
) if the alarm device is activated.
• 1 digital input - An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass break
detectors, etc. When a signal is received the
state
changes and the input becomes
active (shown under
Event Configuration > Port Status
).
• Auxiliary power and GND
Function Pin
number
Notes
Specifications
Transistor
Output
4
Uses an open-collector NPN transistor with
the emitter connected to the GND pin. If
used with an external relay, a diode must be
connected in parallel with the load, for pro-
tection against voltage transients.
Max load = 50mA
Max voltage = 24V DC
(to the transistor)
Digital Input
3
Connect to GND to activate, or leave float-
ing (or unconnected) to deactivate.
Must not be exposed to
voltages greater than
10V DC
3.3V DC
Power
2
Can be used to power auxiliary equipment.
Max load = 50mA
GND
1
Summary of Contents for 27505R1