I/O Connection
3.1.2
Isolated Digital Output
The figure shows how to connect between an output channel and the system.
If an external voltage 5~30 VDC is applied to an isolated output channel, the current will flow
from the external voltage source to the system.
Please note that the current through each DO channel should not exceed 200 mA.
3.1.3
Isolated Trigger/Latch Input
The figure shows how to connect between external input source and the system.
Each of the isolated trigger input channels accepts 0~30 VDC with sink type.