UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
99 - 141
Index
2331h
Name
AO Ramp Down
Object Type
ARRAY
Data Type
UNSIGNED16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Ramp Down
Access
RW
PDO Mapping
No
Value Range
0 to 60,000
Default Value
1000 [ms]
2.4.18. Object 2340h: AO Control Input Source
This object defines the type of input that will be used to control the analog (or digital) output as shown in the
logic flowchart in Figure 12. The available control sources on the 2IN-2OUT-SIG-CO controller are listed in
Table 22. Not all sources would make sense to control the AO, and it is the us
er’s responsibility to select a
source that makes sense for the application.
Object Description
Index
2340h
Name
AO Control Input Source
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Control Input Source
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (control not used)
2.4.19. Object 2341h: AO Control Input Number