UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
103 - 141
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Override Input Number
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (null control source)
2.4.25. Object 2362h: AO Override Response
This object determines how the override command will respond to the input state. The options for this object
are listed in Table 19.
Object Description
Index
2362h
Name
AO Override Response
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Override Response
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (Override When On)
2.4.26. Object 2370h: AO Feedback Field Value
This read-only object reflects the actual measured feedback of an output. It can be mapped to a PDO for
diagnostic purposes. It will be scaled in the physical unit of the output, dependent on type, with the resolution
defined in object 6332h AO Decimal Digits FV.
Object Description
Index
2370h
Name
AO Feedback Field Value