background image

 

 
User Manual UMAX030541. Version V1                                                                                                              116-116 

5  VERSION HISTORY 
 

Version  Date 

Author 

Modifications 

March 5th, 2021 

Jessica Chen 

Initial Draft 

March 15

th

, 2021 

Jessica Chen 

Added Weight and Response time 

April 8

th

, 2021 

Jessica Chen 

Modified Table of Contents 

May 31st, 2021 

Jessica Chen 

Updated Drawing 

June 11, 2021 

Amanda Wilkins 

Updated weight 

 

Summary of Contents for AX030541

Page 1: ...USER MANUAL UMAX030541 Version V1 CAN TO 4 ANALOG OUTPUTS CONTROLLER With CANopen USER MANUAL P N AX030541...

Page 2: ...Byte or Bit NMT Network Management RO Read Only Object RPDO Received Process Data Object RW Read Write Object SDO Service Data Object TPDO Transmitted Process Data Object WO Write Only Object REFERENC...

Page 3: ...t 100Ch Guard Time 46 3 2 6 Object 100Dh Life Time Factor 46 3 2 7 Object 1010h Store Parameters 47 3 2 8 Object 1011h Restore Parameters 48 3 2 9 Object 1016h Consumer Heartbeat Time 50 3 2 10 Object...

Page 4: ...90 3 4 30 Object 3yz8h LTyz Output Y Axis PV 90 3 4 31 Object 3300h Logic Block Enable 91 3 4 32 Object 3310h Logic Block Selected Table 91 3 4 33 Object 3320h Logic Block Output PV 92 3 4 34 Object...

Page 5: ...4 65 Object 5030h Processor Temperature Field Value 109 3 4 66 Object 5031h Enable Error Detection on Temperature 110 3 4 67 Object 5032h Over Temperature Threshold 110 3 4 68 Object 5033h Hysteresis...

Page 6: ...The controller has 4 Digital Analog outputs that can be configured as Analog Current Analog Voltage Digital PWM Digital Frequency and Digital ON OFF All outputs can be configured to use any of the on...

Page 7: ...x from the write mappable object 6220h DO Write State will be used as the control signal The Enable and Override Inputs and Responses for a digital output are the same as for an Analog Output and are...

Page 8: ...s the input will have built in hysteresis as shown in Figure 1 This relationship is true for any function block that has a non digital input mapped to a digital control Figure 2 Analog Input Read as D...

Page 9: ...s When the output type is changed all objects related to the output scaling PV Decimal Digits PV etc are automatically updated by default Object 5550h Enable Auto Updates enables disables automatic up...

Page 10: ...minimum and maximum FV points as shown in the figure Figure 4 Analog Output Linear Scaling PV to FV The controller allows for the PV input can be selected from the list of the logical function blocks...

Page 11: ...stant Function Block 1 5010h sub index 1 always FALSE 2 5010h sub index 2 always TRUE 3 5010h sub index 3 Constant FV 3 4 5010h sub index 4 Constant FV 4 5 5010h sub index 5 Constant FV 5 6 5010h sub...

Page 12: ...gic 3 4 3xy8h Lookup Table Selected by Logic 4 NOTE The following options should be considered for diagnostic feedback and should not be selected as a control source for logic inputs i e lookup table...

Page 13: ...Temperature Measured N A N A 1 fixed Whichever value is smaller Whichever value is larger Table 7 Scaling Limits per Control Source As shown in Figure 5 the Output FV will be calculated based on the F...

Page 14: ...F 5 Enable When OFF Else Keep Last Value Table 9 Object 2352h AO Enable Response Options Table 10 shows options for object 2362h AO Override Response respectively In both cases the default responses a...

Page 15: ...Logic Flowchart Under normal conditions i e when the control input is driving the output as shown in the green box there are ramping objects that can be applied to soften the output response Object 23...

Page 16: ...deration how this affects the accuracy and stability of the outputs When the outputs are in Output PWM mode object 2380h can be used to change the desired frequency of the waveform while when in Outpu...

Page 17: ...sub index 1 which defines the X Axis Type By default the table have a Data Response output 0 Alternatively it can be selected as a Time Response 1 There are two or three other key parameters that will...

Page 18: ...e of 0 to 100 In fact so long as all the data in the Y Axis is 0 Y i 100 where i 1 to 11 then other function blocks using the lookup table as a control source will have 0 and 100 as the Scaling 1 and...

Page 19: ...any input value between XN 1 to XN will result in an output from the lookup table function block of YN Recall LTyz Point Response sub index 1 defines the X Axis type Figure 7 shows the difference bet...

Page 20: ...ick Deadband Response To summarize Table 12 outlines the different responses that can be selected for object 3yz4h both for the X Axis type and for each point in the table Sub Index Value Meaning 1 0...

Page 21: ...ontrol input is ON the output will be changed over a period of time based on the profile in the lookup table Once the profile has finished i e reached index 11 or an Ignored response the lookup table...

Page 22: ...User Manual UMAX030541 Version V1 22 116 1 5 Programmable Logic Function Block The programmable logic blocks LB x 3 functions are not used by default Figure 9 Logic Block Objects...

Page 23: ...Block Selected Table Note In this document the term LB x 3 refers to Logic Blocks 1 to 3 Due to the CANopen Object indices Logic Block 1 begins at 3401h where x in this case is 4 Therefore an LB x 3 a...

Page 24: ...User Manual UMAX030541 Version V1 24 116 Figure 10 Logic Block Flowchart...

Page 25: ...able B Objects 3x31h 3x32h and 3x33h are the conditions evaluated for selecting Table C Argument 1 is always a logical output from another function block as listed in Table 5 As always the input is a...

Page 26: ...available i e set to Control Source Not Used Table 15 LB x 3 Condition Evaluation Results 1 5 2 Table Selection In order to determine if a particular table will be selected logical operations are per...

Page 27: ...s False If Cnd1 True Cnd2 True Cnd3 True Then Use Table Cnd1 And Cnd2 Or Cnd3 To be used only when all three conditions are relevant If both Condition 1 and Condition 2 are True OR Condition 3 is True...

Page 28: ...Table Block Number Table B Lookup Table Block Number Table C Lookup Table Block Number 1 1 2 3 2 4 5 6 3 7 8 9 Table 18 LB x 3 Default Lookup Tables If the associated Lookup Table YZ where YZ equals 3...

Page 29: ...ath Y Input Source and 4y01h Math Y Input Number Here y 1 to 4 corresponding the Math 1 Math 4 Inputs are converted into a percentage value based on objects 4y20h Math Y Scaling 1 FV and 4y22h Math Y...

Page 30: ...and InB are True 9 NAND True when InA and InB are not both True 10 XOR True when InA InB is True but not both 11 XNOR True when InA and InB are both True or False 12 Result InA plus InB 13 Result InA...

Page 31: ...ata i e input measured out of range is always treated as a 0 0 input into the function For the arithmetic functions 12 to 17 it is recommended to scale the data such that the resulting operation will...

Page 32: ...ng 2 PV have been mentioned in Section 1 3 Table 7 These objects allow for additional data received on a CANopen RPDO to be mapped independently to various function blocks as a control source The scal...

Page 33: ...is measured the object 5025h Power Fault Shutdown Outputs must be set to true Whereas the object 5034h Over Temperature Shutdown disables the outputs when the unit is overheating An appropriate EMCY...

Page 34: ...34 116 When using the CAN 4AOUT as a stand alone controller where 5555h is set to TRUE it is recommended to disable all TPDOs set the Event Timer to zero so that it does not run with a continuous CAN...

Page 35: ...nd Pinout Figure 13 Housing Dimensions PIN FUNCTION 1 Analog GND 12 Analog GND 2 Output 1 11 CAN_L 3 Output 2 10 CAN_H 4 Output 3 9 CAN_Shield 5 Output 4 8 Power 6 Analog GND 7 Power Note CANopen is a...

Page 36: ...ly with connectors facing left and right to reduce likelihood of moisture entry The CAN wiring is considered intrinsically safe The power wires are not considered intrinsically safe and so in hazardou...

Page 37: ...tocol to Update The only means by which the Node ID and Baudrate can be changed is to use Layer Settling Services LSS and protocols as defined by CANopen standard DS 305 Follow the steps below to conf...

Page 38: ...ther response is a failure Item Value COB ID 0x7E4 Length 3 Data 0 0x17 cs 23 for store configuration Data 1 0x00 Data 2 0x00 Set the module state to LSS operation by sending the following message Not...

Page 39: ...ll send the following response any other response is a failure Item Value COB ID 0x7E4 Length 3 Data 0 0x13 cs 19 for configure bit timing parameters Data 1 0x00 Data 2 0x00 Activate bit timing parame...

Page 40: ...end the following response any other response is a failure Item Value COB ID 0x7E4 Length 3 Data 0 0x17 cs 23 for store configuration Data 1 0x00 Data 2 0x00 Set the module state to LSS operation by s...

Page 41: ...7E5h and received 7E4h by the tool when the baudrate was changed to 250 kbps using the LSS protocol The other image right shows what was printed on an example debug RS 232 menu while the operation too...

Page 42: ...No 1011 Restore Default Parameters ARRAY UNSIGNED32 RW No 1016 Consumer Heartbeat Time ARRAY UNSIGNED32 RW No 1017 Producer Heartbeat Time VAR UNSIGNED16 RW No 1018 Identity Object RECORD RO No 1020...

Page 43: ...0020h alarm block 0040h 0800h reserved 1000h reserved 2000h lookup table block manufacturer specific 4000h programmable logic block manufacturer specific 8000h miscellaneous block manufacturer specif...

Page 44: ...still active The controller has a limitation of a maximum of 4 errors in the list If the device registers more errors the list will be truncated and the oldest entries will be lost The error codes st...

Page 45: ...ive Overload Vps Undervoltage 00h Unspecified 3000h Generic Voltage 20004000h 20h Positive Overload Over Temp 00h Unspecified 4000h Device Temperature 00008100h 00h RPDO Timeout 00h Unspecified 8100h...

Page 46: ...dard recommends that newer networks do not use the life guarding protocol but rather heartbeat monitoring instead Both life guarding and heartbeats can NOT be active simultaneously Object Description...

Page 47: ...oller will store the parameters in non volatile memory and then confirm the SDO transmission By read access the object provides information about the module s saving capabilities For all sub indexes t...

Page 48: ...restoring of parameters by mistake the device restores the defaults only when a specific signature is written to the appropriate sub index The signature is load The load action on either CAN buses wi...

Page 49: ...Range 4 Default Value 4 Sub Index 1h Description Restore all default parameters Access RW PDO Mapping No Value Range 0x64616F6C write access 1h read access Default Value 1h Sub Index 2h Description R...

Page 50: ...ts 31 24 23 16 15 0 Value Reserved 00h Node ID Heartbeat time Encoded as UNSIGNED8 UNSIGNED16 Object Description Index 1016h Name Consumer heartbeat time Object Type ARRAY Data Type UNSIGNED32 Entry D...

Page 51: ...he format of the data is as shown below MSB LSB Major revision number object dictionary Hardware Revision Software Version Object Description Index 1018h Name Identity Object Object Type RECORD Data T...

Page 52: ...s a hexadecimal value showing day month year as per the format below The time value at sub index 2 is a hexadecimal value showing the time in a 24 hour clock MSB LSB Day in 1 Byte Hex Month in 1 Byte...

Page 53: ...d defined in the Event Timer of the associated communication objects see Section 3 2 14 for more information or if a lifeguard or heartbeat message is not received as expected And output faults are de...

Page 54: ...g No Value Range See above Default Value 1 No State Change Sub Index 5h Description Analog Output Fault AO1 and AO4 Access RW PDO Mapping No Value Range See above Default Value 1 No State Change 3 2 1...

Page 55: ...00 Node ID Sub Index Value Object 0 3 Number of mapped application objects in PDO 1 0x25000110 Extra Received 1 PV 2 0x25000210 Extra Received 2 PV 3 0x25000310 Extra Received 3 PV 4 0 Not used by def...

Page 56: ...Node ID C0000000h RPDOx Node ID Node ID Node ID of the module The RPDO COB IDs are automatically updated if the Node ID is changed by LSS protocol 80000000h in the COB ID indicates that the PDO does...

Page 57: ...valid default mappings defined see below only TPDO1 is enabled by default i e TPDO exists TPDO1 Mapping at Object 1A00h Default ID 0x180 Node ID Sub Index Value Object 0 4 Number of mapped applicatio...

Page 58: ...ect Type RECORD Data Type PDO Communication Record Entry Description Sub Index 0h Description Number of entries Access RO PDO Mapping No Value Range 5 Default Value 5 Sub Index 1h Description COB ID u...

Page 59: ...ge See value definition in DS 301 Default Value 0 Sub Index 4h Description Compatibility entry Access RW PDO Mapping No Value Range UNSIGNED8 Default Value 0 Sub Index 5 Description Event timer Access...

Page 60: ...Digits PV ARRAY UNSIGNED8 RW No 6310 AO Output Type ARRAY UNSIGNED16 RW No 6332 AO Decimal Digits FV ARRAY UNSIGNED8 RW No 6340 AO Fault Mode ARRAY UNSIGNED8 RW No 7300 AO Output Process Value ARRAY I...

Page 61: ...pported Access RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4h x 1 to 4 Description DOx Write State Access RW PDO Mapping Yes Value Range 0 OFF or 1 ON Default Value 0 OFF 3 3 2 Obj...

Page 62: ...ult State 1 Output Line Object Type ARRAY Data Type UNSIGNED8 Entry Description Sub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h...

Page 63: ...fined in Table 4 Object Description Index 6310h Name AO Output Type Object Type ARRAY Data Type UNSIGNED16 Entry Description Sub Index 0h Description Largest sub index supported Access RO PDO Mapping...

Page 64: ...ange 0 to 4 Default Value 3 mv 3 3 7 Object 6340h AO Fault Mode This object defines how an analog output shall response when a fault condition is detected on any control input as described in Table 11...

Page 65: ...Sub Index 1h to 4h x 1 to 4 Description AOx Process Value Access RW PDO Mapping Yes Value Range Integer16 Default Value No 3 3 9 Object 7320h AO Output Scaling 1 PV This object defines the minimum val...

Page 66: ...sical unit of the output dependent on range with the resolution defined in object 6332h AO Decimal Digits FV The value can be set anywhere within the allowable output range as outlined in Table 4 This...

Page 67: ...ub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4h x 1 to 4 Description AOx Scaling 2 PV Access RW PDO Mapping No Value Range...

Page 68: ...s a result of the output logic described in Section 1 3 and the scaling applied as shown in Figure 7 It is defined in the physical unit of the output dependent on range as outlined in Table 4 The reso...

Page 69: ...al unit of the output dependent on type with the resolution defined in object 6332h AO Decimal Digits FV Object Description Index 7341h Name AO Fault Field Value Object Type ARRAY Data Type INTEGER16...

Page 70: ...dback Field Value ARRAY INTEGER16 RO Yes 2380 AO Output Frequency ARRAY UNSIGNED16 RW No 2500 EC Extra Received Process Value ARRAY INTEGER16 RW Yes 2502 EC Decimal Digits PV ARRAY UNSIGNED8 RW No 252...

Page 71: ...Source ARRAY UNSIGNED8 RW No 4y01 Math Y Input Number ARRAY UNSIGNED8 RW No 4y02 Math Y Function Number ARRAY UNSIGNED8 RW No 4y03 Math Y Input Decimal Digits FV ARRAY UNSIGNED8 RW No 4y20 Math Y Inp...

Page 72: ...R UNSIGNED8 RW No 5550 Enable Auto Updates VAR UNSIGEND8 RW No 5555 Start in Operational Mode VAR BOOLEAN RW No 5B50 Change Baud Rate VAR UNSIGNED8 RW No 5B51 Change Node ID VAR UNSIGNED8 RW No Where...

Page 73: ...ata Type UNSIGNED16 Entry Description Sub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4h x 1 to 4 Description DOx Blink Rate...

Page 74: ...IGNED8 Entry Description Sub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4h x 1 to 4 Description DOx Polarity Access RW PDO...

Page 75: ...the time it will take to ramp from the minimum output PV to the maximum as defined by objects 7321h and 7323h It can be used to soften the response to a step change at the input The physical unit for...

Page 76: ...cess RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4h x 1 to 4 Description AOx Ramp Down Access RW PDO Mapping Yes Value Range 0 to 60 000 Default Value 1000 ms 3 4 7 Object 2340h AO...

Page 77: ...n Figure 5 The available control numbers are dependent on the source selected as shown in Table 6 Once selected the control represents the process value X Axis input in Figure 9 Objects 6302h 7320h 73...

Page 78: ...n Sub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4h x 1 to 4 Description AOx Control Response Access RW PDO Mapping No Valu...

Page 79: ...er of the source that will be used to enable disable the analog or digital output as shown in the logic flowchart in Figure 5 The available control numbers are dependent on the source selected as show...

Page 80: ...PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4h x 1 to 4 Description AOx Enable Response Access RW PDO Mapping No Value Range See Table 9 Default Value 3 Enable When Off Else Shut Off...

Page 81: ...the number of the source that will be used to override the analog outputs as shown in the logic flowchart in Figure 5 The available control numbers are dependent on the source selected as shown in Tab...

Page 82: ...AOx Override Response Access RW PDO Mapping No Value Range See Table 10 Default Value 0 Override When On 3 4 16 Object 2370h AO Feedback Field Value This read only object reflects the target Output F...

Page 83: ...ARRAY Data Type UNSIGNED16 Entry Description Sub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4h x 1 to 4 Description AOx Ou...

Page 84: ...ger16 in the process value object Object Description Index 2502h Name EC Decimal Digits PV Object Type ARRAY Data Type UNSIGNED8 Entry Description Sub Index 0h Description Largest sub index supported...

Page 85: ...8 to 2522h sub index X Default Value 0 3 4 21 Object 2522h EC Scaling 2 PV This object defines the maximum value of the extra control source It used as the Scaling 2 value by other functions blocks wh...

Page 86: ...Not Used disables the associated lookup table function block Object Description Index 3yz0h where yz 01 to 10 Name LTyz Input X Axis Source Object Type VARIABLE Data Type UNSIGNED8 Entry Description...

Page 87: ...4 Object Description Index 3yz2h where yz 01 to 10 Name LTyz X Axis Decimal Digits PV Object Type VARIABLE Data Type UNSIGNED8 Entry Description Sub Index 0h Access RW PDO Mapping No Value Range 0 OFF...

Page 88: ...NED8 Entry Description Sub Index 0h Access RW PDO Mapping No Value Range 0 to 4 Default Value 0 3 4 27 Object 3yz5h LTyz Point Response This object determines the Y Axis output response to changes in...

Page 89: ...ject is constrained such that X1 cannot be less than the Scaling 1 value of the selected control source number and X11 cannot be more than the Scaling 2 value The rest of the points are constrained by...

Page 90: ...Name LTyz Point Y Axis PV Object Type ARRAY Data Type INTEGER16 Entry Description Sub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 11 Default Value 11 Sub Ind...

Page 91: ...Description Sub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 3 Default Value 3 Sub Index 1h to 3h x 1 to 3 Description LBx Enable Access RW PDO Mapping No Valu...

Page 92: ...table interpreted as a percentage The limits for the percentage conversion are based on the range of the lookup tables Y Axis Output PV as shown in Table 7 This value has a fixed decimal digit value...

Page 93: ...Value Range 3 Default Value 3 Sub Index 1h to 3h y A to C Description LB x 3 Lookup Table Y Number Access RW PDO Mapping No Value Range 1 to 10 Default Value See Table 18 3 4 35 Object 3x02h LB x 3 F...

Page 94: ...unction B Condition 1 3 4 40 Object 3x22h LB x 3 Function B Condition 2 3 4 41 Object 3x23h LB x 3 Function B Condition 3 3 4 42 Object 3x31h LB x 3 Function C Condition 1 3 4 43 Object 3x32h LB x 3 F...

Page 95: ...alue Range See Table 5 Default Value 3 Constant PV Sub Index 4h Description Argument 2 Number Access RW PDO Mapping No Value Range See Table 6 Default Value 3 Constant FV 1 Sub Index 5h Description Op...

Page 96: ...the process value that would correspond to 0 output from the math calculation The object would apply the resolution defined in object 4532h Math Output Decimal Digits PV The physical unit is undefine...

Page 97: ...g No Value Range 4 Default Value 4 Sub Index 1h to 4h Y 1 to 4 Description Math Y Output Scaling 2 PV Access RW PDO Mapping No Value Range 32768 to 32767 Default Value 10000 100 00 3 4 48 Object 4030h...

Page 98: ...Decimal Digits PV Object Type ARRAY Data Type UNSIGNED8 Entry Description Sub Index 0h Description Largest sub index supported Access RO PDO Mapping No Value Range 4 Default Value 4 Sub Index 1h to 4...

Page 99: ...t Value 0 control source not used 3 4 51 Object 4y01h Math Y Input Number This object defines the number of the input source that will be used in the math calculation The available control numbers are...

Page 100: ...lock being configured and the Function Number is 0 this object is ignored For more details refer to Section 1 6 Object Description Index 4y01h y 1 to 4 Name Math Y Input Number Object Type ARRAY Data...

Page 101: ...ect 4y20h Math Y Input Scaling 1 FV This object defines the input field value that would correspond to 0 when scaling the input for use in the math calculation All inputs are normalized to a percentag...

Page 102: ...he physical unit would match that of the input source Object Description Index 4y22h y 1 to 4 Name Math Y Input Scaling 2 FV Object Type ARRAY Data Type INTEGER16 Entry Description Sub Index 0h Descri...

Page 103: ...lue 100 1 0 3 4 57 Object 4y50h Math Y Operator This object defines the actual operators that will be used in each stage of a math calculation as described in Section 1 6 The options for this object a...

Page 104: ...are ten other sub indexes provide for other unconstrained data Object Description Index 5010h Name Constant Field Value Object Type ARRAY Data Type FLOAT32 Entry Description Sub Index 0 Description L...

Page 105: ...t Value 2 718282 Sub Index 5 Description Constant FV 5 Access RW PDO Mapping No Value Range Float32 Default Value 1 414214 Sub Index 6 Description Constant FV 6 Access RW PDO Mapping No Value Range Fl...

Page 106: ...lt Value 10 00 Sub Index 11 Description Constant FV 11 Access RW PDO Mapping No Value Range Float32 Default Value 20 00 Sub Index 12 Description Constant FV 12 Access RW PDO Mapping No Value Range Flo...

Page 107: ...Data Type FLOAT32 Entry Description Sub Index 0h Access RO PDO Mapping Yes Value Range 0 to 70 V Default Value No 3 4 60 Object 5021h Enable Error Detection on Power Supply This write able object is...

Page 108: ...hold This object is used to set the value at which a supply fault will trigger if the measured supply falls above it If object 5021h is disabled this value is ignored For more information please refer...

Page 109: ...d in the system For more information please refer to Section 1 7 Object Description Index 5025h Name Enable Power Supply Fault Disables Outputs Object Type VARIABLE Data Type UNSIGNED8 Entry Descripti...

Page 110: ...5021h Name Enable Error Detection on Temperature Object Type VARIABLE Data Type UNSIGNED8 Entry Description Sub Index 0h Access RW PDO Mapping No Value Range FALSE TRUE Default Value TRUE 1 3 4 67 Obj...

Page 111: ...ess RW PDO Mapping No Value Range 0 150 DegC Default Value 25 DegC 3 4 69 Object 5034h Enable Temperature Fault Shutdown This write able object is available to enable shutdown when there are faults on...

Page 112: ...d only when running the controller as a stand alone module This should always be set FALSE whenever it is connected to a standard master slave network Object Description Index 5555h Name Start in Oper...

Page 113: ...nge 0 8 Default Value 4 125k 3 4 73 Object 5B51h Change Node ID This object is used to change the node ID of the module Object Description Index 5B51h Name Change Node ID Object Type VARIABLE Data Typ...

Page 114: ...short circuit condition self recovering when the short is removed Table 1 0 Outputs Analog Outputs Up to 4 signal outputs are available the output mode voltage current or digital the minimum and maxi...

Page 115: ...ng left and right to reduce likelihood of moisture entry The CAN wiring is considered intrinsically safe The power wires are not considered intrinsically safe and so in hazardous locations they need t...

Page 116: ...ate Author Modifications 1 March 5th 2021 Jessica Chen Initial Draft March 15th 2021 Jessica Chen Added Weight and Response time April 8th 2021 Jessica Chen Modified Table of Contents May 31st 2021 Je...

Page 117: ...m Please provide the following information when requesting an RMA number Serial number part number Axiomatic invoice number and date Hours of operation description of problem Wiring set up diagram app...

Reviews: