M 5 2 2 3 3 D E M O
S E P T E M B E R 2 5 , 2 0 0 6
6
•
RJ-45 Ethernet Connector
•
Type B USB connector
•
DB9
Serial
Connector
•
2.0mm Barrel Power Input
•
2pos, screw type, terminal block
•
Supplied with DB9 Serial Cable, USB cable, Ethernet Cable, Support CD, and CodeWarrior Development
Studio CD
Specifications:
Board Size 3.0” x 43.0”
Power Input: +5 - +1520VDC, 9VDC typical
REFERENCES
Reference documents are provided on the support CD in Acrobat Reader format.
M52233DEMO_UG.pdf
M52233DEMO User Guide (this document)
M52233DEMO_SCH_D.pdf
M52233DEMO Schematic, Rev D
M52233DEMO_Silk_D.pdf
M52233DEMO Top Silkscreen, Rev D
CFPRM.pdf
ColdFire Programmers Reference Manual
AZ131.pdf
Hands-On Workshop: Dynamic Web Page
Server with the MCF5223x Family
ColdFire_Web_Server_with_Labs_Axman.zip Example file for use with Hands-On Workshop:
GETTING STARTED
The M52233DEMO ships from the factory with a USB stack and open-source RTOS from In-
terNiche Technologies preloaded. Refer to the Hands-On Workshop: Dynamic Web Page
Server with MCF5223x Family (AX131.pdf) on the Axiom Support CD for details on how to get
started quickly. Table 1 below shows the default jumper configuration for the M52233DEMO.
Table 1: Default Jumper Configuration
● ● ●
VB
VDD
Selects power input from integrated USB
BDM
PWR_SEL
● ● ●
● ● ●
VX
EN
BDM
E
N
POT
E
N
POT_EN must be installed.
BDM_EN and VX_EN jumpers are "don’t
care" and may be left on or taken off. These
shunts are installed at the factory.
LED_EN
● ●
ON
Enable user LED’s
CTS
● ●
ON
RTS
● ●
ON
CTS and RTS are “don’t care”
RXD
● ●
ON
Enable RS-232 communications
TXD
● ●
ON