Axiom ED150A User Manual Download Page 3

I/O AND CONTROL OPERATIONS

MAINS IN - 

Powercon® NAC3FCA power input connector (blue). To switch the amplifier on, insert the Powercon® 

connector and turn it clockwise into the ON position. To switch the amplifier off, pull back the switch on the 

connector and turn it counter-clockwise into the POWER OFF position.

WARNING!

 

In the case of product failure or fuse replacement, disconnect the unit completely from the 

mains power. The power cable must only be connected to a socket corresponding to the specifications 

indicated on the amplifier unit. The power supply must be protected by a suitably rated thermo-magnetic 

breaker.

 

Preferably use a suitable switch to power on the whole audio system leaving the Powercon® 

always connected to each speaker, this simple trick extend the life of the Powercon® connectors.

MAINS OUT -

 Powercon® NAC3FCB power output connector (grey). This is 

connected in parallel with the MAINS ~ / IN. The maximum load applicable 

depends on the mains voltage. With 230V~ we suggest to link a maximum 

of 5 ED120A loudspeakers, with 120V~ we suggest to link a maximum of 3 

ED120A loudspeaker.

INPUT - 

Audio  signal  input  with  locking  XLR  connector.  It  has  a  fully 

electronically  balanced  circuitry  including  AD  conversion  for  the  best  S/N 

ratio and input headroom.

LINK - 

A direct connection from the input connector to link other speakers 

with same audio signal.

ON - 

This LED indicates power on status.

SIGN/LIMIT - 

This LED lights in green to indicate the presence of the signal and lights in red when an internal 

limiter reduces the input level.

GND LIFT -

 This switch lift the ground of the balanced audio inputs from the earth-ground of the module.

PRESET BUTTON - 

This button has two function:

1)

 Pressing it while powering on the unit:

ID ASSIGN

 

the internal DSP assigns a new ID to the unit for the PRONET remote 

control  operation.  Each  loudspeaker  must  have  a  unique  ID  to  be 

visible in the PRONET network. When you assign a new ID, all the other 

loudspeakers with the ID already assigned must be ON and connected 

to the network.

2)

 Pressing it with the unit ON you can select the DSP PRESET. The selected PRESET is 

indicated by the corresponding LED:

STANDARD 

Suited  for  a  typical  use  of  a  standalone  loudspeaker  for  any  sound 

reinforcement situation.

LOW CUT 

This PRESET is the same of the previous with an high pass filter (110Hz 

@ 48 dB/oct.) to use the loudspeaker in combination with a subwoofer.

MONITOR 

Suited for the use of the system as a stage monitor, in this preset the 

deep lows are attenuated in order to compensate the floor postion, the 

mid-low frequencies are enhanced for a better presence and the mid-

high frequencies are reduced for an improved feedback rejection.

USER 

This LED lights when the USER PRESET is loaded. This preset corresponds 

to USER MEMORY no. 1 of the DSP and, as a factory setting, it’s the same to STANDARD. If you want to modify it, you have to 

connect the unit to a PC, edit the parameters with PRONET software and save the PRESET into USER MEMORY no. 1.

 Note: see 

also the PRONET example further on this manual.

NETWORK IN/OUT -

 These are a standard RJ45 CAT5 connectors (with optional NEUTRIK NE8MC RJ45 cable connector carrier), used for PRONET 

network transmission of remote control data over long distance or multiple unit applications. 

TERMINATE -

 In a PRONET network the last loudspeaker device must be terminated (with an inner load resistance) especially in a long run cabling: 

press this switch if you want to terminate the unit.

POWER AMPLIFIERS

Powering the loudspeaker drivers is a well-proven DA series Class D amplifier module used in many of the Axiom powered loudspeaker products, 

with audio quality that is comparable to some of the best analogue Class A-B designs, but with the benefit of lower weight and better than 90% 

efficiency. The output power is optimised specifically to the drive units, sharing 900 watts between both woofers and delivering 300 watts to the 

high frequency band. The DA series amplifier delivers superior definition at all frequencies, and very high dynamic range with low distortion even 

at maximum level, so your sound remains clean and dynamic even when loud.

SIGNAL PROCESSING

The system processing is based on the CORE DSP platform, which has been designed by the PROEL R&D Laboratories using one of the most 

advanced SHARC DSP for audio application. It features 40bit, 96kHz floating point resolution and high quality 24bit AD/DA converters, for a perfect 

signal integrity, a dynamic range in excess of 110dB and a superior sonic performance. Thanks to its massive processing power, the CORE platform 

is capable of providing the most sophisticated algorithms for speaker processing, together with remote control and networking capability.

The PRONET control software, working on a solid and reliable CANBUS based network protocol, provides an intuitive interface for the remote 

control of the whole system, with the possibility of eqing, delaying, increasing the protections and monitoring the status of the amplifier.

Summary of Contents for ED150A

Page 1: ...o be used as a low profile stage monitor with its 35 tapered side and in this situation the HF horn can be rotated to maintain the best coverage pattern for performers both near to and further away from the monitor ED150A cabinet is an unobtrusive and compact format designed for a multitude of near field applications such as theatre under balcony fill stage front fill delay speaker bar and restaur...

Page 2: ...on and other available accessories SPARE PARTS NAC3MPA Neutrik Powercon BLUE SOCKET 98NEOS15SW4 15 woofer 3 VC 4 ohm NAC3MPB Neutrik Powercon WHITE SOCKET 98DRI2065 1 4 2 4 VC compression driver 8 ohm 91AMDED150A Power amplifier module with mechanical assembly 98MBN2065 titanium diaphragm for 1 4 driver 2 Unscrew the 4 screws fixing the horn and rotate the horn by 90 turn 90 INSTRUCTION FOR ROTATIN...

Page 3: ...ofer MONITOR Suited for the use of the system as a stage monitor in this preset the deep lows are attenuated in order to compensate the floor postion the mid low frequencies are enhanced for a better presence and the mid high frequencies are reduced for an improved feedback rejection USER This LED lights when the USER PRESET is loaded This preset corresponds to USER MEMORY no 1 of the DSP and as a...

Page 4: ...reater than 1 in the network cannot exist two devices with the same ID In order to correctly assign a new available ID to each device for working properly in a Pronet AX network follow these instructions 1 Switch off all the devices 2 Connect them correctly to the network cables 3 TERMINATE the end device in the network connection 4 Switch on the first device keep pressed PRESET button on the cont...

Page 5: ...15 10 0 10 15 25 30 40 55 70 For installing the speaker using the C bracket follow these instructions a Install the C bracket to the the wall or to the truss b Mount the two rotation brackets on the top and bottom of the loudspeker using the screws 1 c Carefully put the loudspeaker into the C bracket 2 then screw in the screws 3 to fix it to the C bracket d Aim the loudspeaker and tighten the scre...

Page 6: ...roduct receipt SAFETY INSTRUCTIONS To reduce the risk close supervision is necessary when the product is used near children Protect the apparatus from atmospheric agents and keep it away from water rain and high humidity places This product should be site away from heat sources such as radiators lamps and any other device that generate heat This product should be located so that its location or po...

Reviews: