Axiom CX15A User Manual Download Page 6

EDITING USER PRESETS

If you connect the CX15A to a PC, using PRONET Control So  ware you can edit the user presets. In par  cular, the user preset no. 
4-U can be loaded also from the unit’s control panel without the need to connect again the loudspeaker to PRONET.
Here below there is a a brief explana  on about how to edit the main DSP parameters.

In/Out - Level: 

adjusts the input level gain in the range of -30 ÷ +6 dB (this is  a digital control a  er the A/D converter).

In/Out - Input Meter: 

shows the input level signal a  er the A/D converter. Green LED indicates the normal opera  ng level before nominal input 

sensi  vity (+4 dBu), yellow LED indicates that the signal exceeds the nominal sensi  vity, red LED indicates digital clipping and must be avoided.

In/Out - Compressor/Limiter: 

this is a compressor/limiter for the input signal, that can be used to increase loudness and transparency (for the 

best results, we recommend to not change the factory se   ngs).

In/Out - Output Level Trim: 

use these controls in you want to trim 

fi

 nely the level of woofer and HF driver.

In/Out - MUTE: 

these bu  ons can be used to switch o

  the woofer or the HF driver in order to check the system.

In/Out - Input Delay: 

edit this box to apply a delay to the speaker, to be used   pically if you need to align in   me the speaker to another sound 

source. 

Note: a delay higher than 10 mS (3 m) is easily audible and it can be annoying to singers and musicians.

PEQ - EQ1-5: 

5-band full parametric EQ. 

Note: CX15A is already op

Ɵ

 mized for the best performance for wedge monitoring, so we suggest to make 

only small adjustments.

Setup - Device Name: 

here you can assign a unique name at the unit (twelve characters are available).

Setup - Device Group: 

here you assign the unit to a group, so when the LINK func  on on PRONET so  ware is ac  vated, you can automa  cally set 

the same parameters to all the units assigned to the same group.

Summary of Contents for CX15A

Page 1: ...CATION AcousƟcal Remote Controls PRONET control so ware System type 2 way processed coaxial ac ve enclosure Network protocol CANBUS Low frequency transducer One 15 380mm 3 75mm Interleaved Voice Coil 8 Ohm Amplifier Type Class D with Variable Switching Frequency and SMPS Output Power 2000 W High frequency transducer One 1 4 driver 2 4 60mm edgewound aluminium voice coil tanium diaphragm 8 Ohm Main...

Page 2: ...ble accessories SPARE PARTS NAC3MPA Neutrik Powercon BLUE SOCKET 91DA2000 DA2000 Power amplifier module NAC3MPB Neutrik Powercon WHITE SOCKET 91PCAGLED1 Posi on Check LED PCBA 98NCX15WZ8 Coaxial Loudspeaker 15 woofer 1 4 driver 91PCAG00031 DSP Interface PCBA 98MBN1424T tanium diaphragm for 1 4 driver 91DSPKT3 DSP PCBA and Control PCBA 99CXRT15V Loudspeaker protec on metal grid 91CRAX2010 XLR Input...

Page 3: ...wo func on 1 Pressing it while powering on the unit ID ASSIGN the internal DSP assigns a new ID to the unit for the PRONET remote control opera on Each loudspeaker must have a unique ID to be visible in the PRONET network When you assign a new ID all the other loudspeakers with the ID already assigned must be ON and connected to the network 2 Pressing it with the unit ON you can select the DSP PRE...

Page 4: ...NET software has been developed in collaboration with sound engineers and sound designers in order to offer an easy to use tool to setup and manage your audio system With PRONET you can visualize signal levels monitor internal status and edit all the parameters of each connected device Download the PRONET app from the AXIOM website at hƩp www axiomproaudio com clicking on downloads secƟon of the pr...

Page 5: ...ocedure for a device makes the internal network controller to perform two opera ons reset the current ID search the first free ID in the network star ng from ID 1 If no other devices are connected and powered on the controller assume ID 1 that is the first free ID otherwise it searches the next one le free These opera ons ensure that every device has it s own unique ID if you need to add a new dev...

Page 6: ... used to increase loudness and transparency for the best results we recommend to not change the factory se ngs In Out Output Level Trim use these controls in you want to trim finely the level of woofer and HF driver In Out MUTE these bu ons can be used to switch off the woofer or the HF driver in order to check the system In Out Input Delay edit this box to apply a delay to the speaker to be used p...

Page 7: ......

Page 8: ... product receipt SAFETY INSTRUCTIONS To reduce the risk close supervision is necessary when the product is used near children Protect the apparatus from atmospheric agents and keep it away from water rain and high humidity places This product should be site away from heat sources such as radiators lamps and any other device that generate heat This product should be located so that its loca on or p...

Reviews: