POWER AMPLIFIERS

The AX2065A is powered by DA SERIES digital power modules, a new genera  on of CLASS D power ampli

fi

 er with digitally-controlled SMPS.

The innova  ve technology used for these ampli

fi

 ers (including also the use of a variable switching frequency) o

 ers performances at the top of 

the range, such as a superior sound de

fi

 ni  on at any audio frequency, very high dynamics also for low level signals and very low distor  on even at 

the maximum power The superior sound quality can be compared with top-of-the-range AB-class analog systems, while the DA modules feature 
a higher dynamics, very compact size and light weight and e

  ciency above 90%. The DA module employed for powering the AX2065A deliver 

in an ultra-compact package a maximum power of 2000W, 1000W are delivered to the internal speakers, the other 1000W are delivered to the 
AX2065P connected in parallel using the POWER OUT speakon connector.

SIGNAL PROCESSING

The system processing is based on the CORE DSP pla  orm, which has been designed by the PROEL R&D Laboratories using one of the most 
advanced SHARC DSP for audio applica  on. It features 40bit, 96kHz 

fl

 oa  ng point resolu  on and high quality 24bit AD/DA converters, for a perfect 

signal integrity, a dynamic range in excess of 110dB and a superior sonic performance. Thanks to its massive processing power, the CORE pla  orm 
is capable of providing the most sophis  cated algorithms for speaker processing, together with remote control and networking capability.
The PRONET control so  ware, working on a solid and reliable CANBUS based network protocol, provides an intui  ve interface for the remote 
control of the whole system, with the possibility of eqing, delaying, increasing the protec  ons and monitoring the status of the ampli

fi

 er.

PRONET

PRONET so  ware has been developed in collabora  on with sound engineers and sound designers, in order to o

 er an “easy-to-use” tool to setup 

and manage your audio system. With PRONET you can visualize signal levels, monitor internal status and edit all the parameters of each connected 
device.

Download the PRONET app from the AXIOM website at h

Ʃ

  p://www.axiomproaudio.com/ clicking on downloads sec

Ɵ

 on of the product.

The AXIOM ac  ve  loudspeaker  devices 
can be connected in a network and 
controlled by the PRONET software. 
For the network connec  on the PROEL 
USB2CAN converter op  onal  accessory 
is needed. The first time you connect 
a device with the USB2CAN converter, 
Windows O.S. will ask you to install the 
driver files, which you can find in the 
Driver folder within the Pronet applica  on 
folder (by default is C:\Program Files\
Proel\Pronet\Driver, or if you changed it 
<your path>\Driver). Please refer also to 
“Installa  on” and “Drivers” paragraphs in 
the Pronet documenta  on.
The PRONET NETWORK is based on a 
robust, reliable and fast communica  on 
protocol called CANBUS. The devices 
in a PRONET NETWORK are connected 
together with a “linear bus topology”. The 
USB2CAN converter must be connected 
to the network input of the 

fi

 rst device, 

the network output of the 

fi

 rst device is 

connected to the input of the second and 
so on. For the network connec  ons simple 
RJ45 cat.5 or cat.6 ethernet cables can be 
used (please don’t confuse a ethernet 
network with a PRONET network these 
are completely di

 erent and must be fully 

separated also both use the same kind of cable).
The beginning and the end of a PRONET NETWORK must be terminated. One side is terminated by the USB2CAN converter, the other side must 
be terminated pressing the TERMINATE switch on the last device. All devices between these two points must have the TERMINATE switch li  ed.

Assign the ID number

To work properly in a PRONET network each connected device must have a unique iden  

fi

 er number, called ID. By default the USB2CAN PC 

controller has ID=0 and there can be only one PC controller. Every other device connected must have its own unique ID equal or greater than 1: 
in the network cannot exist two devices with the same ID.
An ID number is assigned automa  cally to each devices when they are turned on for the 

fi

 rst   me connected to a network.

In order to correctly assign a new available ID to each device for working properly in a Pronet network, follow these instruc  ons:

1.

 Switch o

  all the devices.

2.

 Connect them correctly to the network cables.

3.

 “TERMINATE” the latest device in the network connec  on.

4.

 Switch on the 

fi

 rst device keep pressed “PRESET” bu  on on the control panel.

5.

 Leaving the previous device switched on, repeat the previous opera  on on the next device, un  l the latest device is turned on.

not pressed

pressed

last device

network

network

AX2065A

USB2CAN

PC NOTEBOOK

USB 2.0 port

AX2065A

AX2065P

AX2065A

AX2065P

SW215A

ST

A

TUS

CO
N

V

ER

TE

R

USB2CAN

CODE:

S/N:

RA
TINGS:

RoHS COMPLIANT

MADE IN IT

AL

Y

USB2CAN

00001

5V ---  200mA

EXAMPLE OF PRONET NETWORK WITH AX2065A AND SW215A

Summary of Contents for AX2065A

Page 1: ...ivers in an ultra compact package a maximum power of 2000W and each AX2065A is able to power an addi onal passive AX2065P module through the available power output on the back panel This feature will allows to assemble very compe ve hybrid solu ons both for rental and installa on applica ons TECHNICAL SPECIFICATION AcousƟcal Remote Controls PRONET control so ware System type Line Array Element Sho...

Page 2: ...lt adaptor SW215A Ac ve Subwoofer DHSS10M20 Sub Speaker ø35mm Pole with M20 screw SW215FA Flyable Ac ve Subwoofer RAINCOV2065 Rain cover for input sockets see hƩp www axiomproaudio com for detailed descripƟon and other available accessories SPARE PARTS NAC3MPA Neutrik Powercon BLUE SOCKET 91DSPKT3 Input DSP module with panel assembly NAC3MPB Neutrik Powercon WHITE SOCKET 98AXM6W16 6 5 woofer 1 5 V...

Page 3: ...to the unit for the PRONET remote control opera on Each loudspeaker must have a unique ID to be visible in the PRONET network When you assign a new ID all the other loudspeakers with the ID already assigned must be ON and connected to the network 2 Pressing it with the unit ON you can select the DSP PRESET The selected PRESET is indicated by the corresponding LED STANDARD This PRESET is suitable f...

Page 4: ...ec on the PROEL USB2CAN converter op onal accessory is needed The first time you connect a device with the USB2CAN converter Windows O S will ask you to install the driver files which you can find in the Driver folder within the Pronet applica on folder by default is C Program Files Proel Pronet Driver or if you changed it your path Driver Please refer also to Installa on and Drivers paragraphs in...

Page 5: ...play angles so the maximum precision is needed for aiming the ver cal array par cularly for long throw applica ons LASER DISTANCE METER This instrument can be useful to measure the height of the ver cal array and to know the distance between FOH Subs and FOH Array for se ng the delay me SMAART or similar acousƟc measurement system These are useful to measure delays phase and response of the system...

Page 6: ...nd applicable safety standards During assembly pay a en on to the possible risk of crushing Wear suitable protec ve clothing Observe all instruc ons given on the rigging components and the loudspeaker cabinets When chain hoists are in opera on ensure that there is nobody directly underneath or in the vicinity of the load Do not under any circumstances climb on the array AIMING and SUSPENDING INSTR...

Page 7: ...ge the weight of the cables from the flying pinpoint by tying them with a tex le fibre rope instead of le ng them hang freely in this way the posi on of the array will be much more similar to the simula on produced by the so ware Pin locking and splay angles set up The figure below shows how to insert correctly the locking pin and how to set up the splay angle between loudspeakers Wind loads When ...

Page 8: ...ower supply mains line only of the type described on the opera ng instruc ons or as marked on the product Connect the apparatus to a power supply using only power cord included making always sure it is in good condi ons WARNING The mains plug is used as disconnect device the disconnect device shall remain readily operable Do not cancel the safety feature assured by means of a polarized line plug o...

Reviews: