Axiom ADA1250 Quick Setup Manual Download Page 3

1

IMPORTANT SAFETY INSTRUCTIONS

 

         

CAUTION

 

1.

  Read these instructions.           

2.

  Keep these instructions.

3.

  Heed all warnings.

4.

  Follow all instructions.

5.

  Do not use this apparatus near water.

6.

  Clean only with dry cloth.

7.

  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.

  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers)  

 

that produce heat. 

9.

  Do not defeat the safety purpose of the polarized or grounding-type plug.  A polarized plug has two blades with one  

 

wider than the other. A grounding type plug has two blades and a third grounding prong.  The wide blade or the third  

 

prong are provided for your safety.  If the provided plug does not fit into your outlet, consult an electrician for   

 

replacement of the obsolete outlet. 

10.

  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the  

 

point where they exit from the apparatus.

11.

  Only use attachments/accessories specified by the manufacturer.

12.

     

 

   

 

 

   

 

Use only with the cart, stand, tripod, bracket,    

 

 

 

 

 

   

 

or table specified by the manufacturer, or sold with the apparatus.  

 

   

 

When a cart is used, use caution when moving the cart/apparatus 

 

   

 

combination to avoid injury from tip-over. 

13.

  Unplug this apparatus during lightning storms or when unused for long periods of time. 

14.

  Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has been damaged in any 

 

way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, 

 

the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 

15.

  Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids, such as vases, are 

 

placed on the apparatus. 

16.

  To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the 

 

AC receptacle. 

17.

  The mains plug of the power supply cord shall remain readily operable. 

18.

  Do not expose batteries to excessive heat such as sunshine, fire or the like.

SAFETY PROCEDURES

 

•  Ensure that you connect your Amplifier only to the type of power  

 

  supply indicated on the rear panel, and ensure that the power  

 

  cord cannot be walked on or otherwise damaged.
•  To prevent electric shock, match wide blade of plug to wide slot, fully   

  insert.
•  Ensure that objects or liquids are not allowed to penetrate the enclosure.
  For any additional information or service, contact:

  AXIOM, 2885 HWY 60  

     

Phone: 

1-866-244-8796

  DWIGHT ON CANADA

  P0A 1H0

The lightning flash with arrowhead 

symbol within an equilateral triangle, 

is intended to alert the user to the 

presence of uninsulated “dangerous 

voltage“ within the product’s enclosure 

that may be of sufficient magnitude to constitute a risk 

of electric shock to persons. 

 

The exclamation point within an 

equilateral triangle is intended to 

alert the user to the presence of 

important operating and maintenance 

(servicing) instructions in the literature 

accompanying the product. 

 

WARNING : To reduce the risk of fire or electric shock, 

do not expose this apparatus to rain or moisture. 

Summary of Contents for ADA1250

Page 1: ...ADA1250 1500ADVANCED DIGITALAMPLIFIER Quick Setup Guide AMPLIFICATEURADA1250 1500 ADVANCED DIGITALAMPLIFIER Guide d installation rapide ...

Page 2: ...hoix sur l un de nos produits Nous avons travaillé d arrache pied pour vous procurer le plus haut niveau de satisfaction possible lors de vos expériences audio et nous allons continuer de déployer tous nos efforts pour faire en sorte que chaque achatAxiompuissereprésenterpourvousuninvestissement audio des plus avisés Axiom est profondément engagé en permanence dans des recherches audio qui permett...

Page 3: ...y way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids such as vases are placed on the apparatus 16 To completely disconnect this apparat...

Page 4: ... the red post and the negative wire is connected to the black post Ensure that there are no loose strands of wire that might cause a short between the positive and negative terminals Branchez un fil d enceinte acoustique à la borne 5 voies de la sortie étiquetée 1 assurez vous que le fil positif soit raccordé à la borne rouge et que le fil négatif le soit à la borne noire Look at the rear panel of...

Page 5: ... votre récepteur A V ou préamplificateur processeur A V possède une sortie 12 volts de mise sous tension à l aide d un fil ayant des fiches de 3 5mm vous pouvez la relier à l entrée mise sous tension trigger de votre ADA1250 1500 La mise en fonction ou hors fonction de votre amplificateur sera gouvernée par votre récepteur A V ou préamplificateur processeur A V Step 8 ÉTAPE 8 The trigger input is ...

Page 6: ...apeau tées par des bornes d attache à cinq voies Elles sont offertes en configuration simple ou double Le câble de haut parleur en vrac La gaine caoutchoutée de fil de haut parleur en vrac est robuste d une flexibilité remarquable et convient aux installations les plus compliquées Ce câble de calibre 12 en cuivre exempt d oxygène est l un des plus toronnés de l industrie Pur à 99 9999 pour cent et...

Page 7: ...sHWDInches DimensionsHWDmm Weightlbs Weightkgs 1000 29dB 1 2volts 54 000uf 5Hz 45kHz 100dB yes no 115or230 yes 5 25 x17 75 x16 75 133x450x425 58 26 1250 29dB 1 5volts 108 000uf 1Hz 45kHz 103dB yes yes 115or230 yes 5 25 x17 75 x16 75 133x450x425 58 26 1500 29dB 2volts 144 000uf 1Hz 50kHz 105dB yes yes 115or230 yes 5 25 x17 75 x16 75 133x450x425 58 26 Gain Sensibilité Pleinepuissanceà8ohms Capacitan...

Page 8: ...nal 1 705 635 3090 Email Courriel info axiomaudio com www axiomaudio com Visit www axiomaudio com manual_index html for this Owner s Manual with live links to further helpful information Pour accéder ŕ des liens actifs associés ŕ de l information et de l aide supplémentaires consultez le Guide du Propriétaire au www axiomaudio com manual_index html ...

Reviews: