Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer to 
the manual for further information. 

This symbol, adjacent to a terminal, indicates that, under normal use, hazardous 
voltages may be present. 

Double insulation

 

 

Safety Precautions 

1.

 

Improper use of this meter can cause damage, shock, injury or death. Read and understand this 

users manual before operating the meter. 
2.

 

Make sure any covers or battery doors are properly closed and secured. 

3.

 

Always disconnect the test leads from any voltage source before replacing the battery or fuses. 

4.

 

Do not exceed the maximum rated input limits. 

5.

 

Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. 

These voltages are considered a shock hazard. 
6.

 

Always discharge capacitors and remove power from the device under test before performing 

Capacitance, Diode, Resistance or Continuity tests. 
7.

 

Remove the battery from the meter if the meter is to be stored for long periods. 

 

Description 

Meter Description 

1.

 

3 3/4 Digit (4000 count) 

2.

 

RELATIVE button 

3.

 

SELECT button 

4.

 

DATA HOLD button 

5.

 

Hz/DUTY button 

6.

 

Function switch 

7.

 

Plastic case 

8.

 

Test leads 

Summary of Contents for AX-MS811

Page 1: ...POCKET AUTORANGING DMM AX MS811 OPERATION MANUAL ...

Page 2: ... and secured 3 Always disconnect the test leads from any voltage source before replacing the battery or fuses 4 Do not exceed the maximum rated input limits 5 Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC These voltages are considered a shock hazard 6 Always discharge capacitors and remove power from the device under test before performing Capacitance ...

Page 3: ...Hz 5000 0Hz 5 000kHz 50 00kHz 500 0kHz 10MHz 2 0 rdg 5d Duty Cycle 0 1 99 Max input voltage 500V AC DC Input Sensitivity 10Vrms min 9 999KHz Frequency Ranges 40Vrms min 99 99KHz Diode Test Test current 1mA max open circuit voltage of 1 5V typical Continuity Check Audible signal if the resistance is 60Ω Display 4000 count 3 digit LCD Over range indication LCD displays OL Polarity Minus sign for neg...

Page 4: ...RNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements Remove the batteries and unplug the line cords Never measure continuity on circuits or wires that have voltage on them 1 Set the function switch to the Ω position 2 Press the SELECT button until nF appears in the display 3 Press the RELATIVE button to zero t...

Page 5: ...exit the relative mode Note The Relative function does not operate in the Frequency function Data Hold Button The Data Hold function allows the meter to freeze a measurement for later reference 1 Press the DATA HOLD button to freeze the display the HOLD indicator will appear 2 Press the DATA HOLD button to return to normal operation Auto Power Off 1 To save power the display automatically turns of...

Reviews: