of thermocouple on the surface or inside the object to be tested. Then you can read temperature from
the screen, and the data is in Centigrade.

3.11. Data holding, B/L

Press the “Hold B/L” switch, the presently measured value is held on LCD, press it again, the function is
cancelled. Press “Hold B/L” key to turn on the backlight

3.12. Automatic power off

• The meter will be into sleeping mode when it works for (15±10) minutes. Press “POWER” key twice to

restart the power.

4. Maintenance of the Instrument

This instrument is precise, and users shall never change its circuit at random.
• Protect the instrument from water, dust and hurl-down.
• Never store or use the instrument in high-temperature, high-humidity, flammable, explosive and

strong-magnetic-field environment;

• Please clean the outer surface of the instrument with wet fabric and gentle detergent, instead of grinding

additives and strong solvents like alcohol, etc.;

• If the instrument is left unused for long term, the battery shall be taken out in order to avoid that the

instrument is eroded by battery weeping;

• When

symbol displays, should replace the battery.

• For replacement of fuse, please use fuse of the same specification and model.
Notes
• Don’t connect the voltage higher than DC1000V or AC750V peak value;
• Don’t use this instrument is the batteries are not installed or the back cover is not fastened;
• Please move the testing probes from tested points and shut down the machine before replacement of

batteries or fuse.

5. Troubleshooting

If your instrument does not work normally, the following methods may help you solve common problems.
If the troubles can not still be eliminated, please contact our maintenance center or dealer.

Summary of Contents for ax-585b

Page 1: ...ion and range to avoid fault operation Please do not measuring before battery isn t installed and back cap isn t firm Do not input any voltage when measure resistance Always remove the test leads before replacing the battery or fuses The following safety symbols may appear in this manual or on the instrument Attention Exists high voltage GND Dual insulation Must refer to manual Low battery 2 Speci...

Page 2: ...Ω other range is 10MΩ Over load protection 250V DC or AC peak value for range 200mV 1000V DC or AC peak value for other ranges 2 2 3 AC Voltage Measurement Range Accuracy Resolution 200mV 0 8 25 0 01mV 2V 0 8 25 0 1mV 20V 0 8 25 1mV 200V 0 8 25 10mV 750V 1 0 25 100mV Input impedance 200mV range 1MΩ and the other is 10 MΩ Overload protection DC1000V or AC750V peak value Frequency response The frequ...

Page 3: ...pplicable to standard sine wave and triangle wave and that for other waveforms more than 200Hz only for reference Display Sine wave RMS Average value response 2 2 6 Resistance Range Accuracy Resolution 200Ω 0 5 10 0 01Ω 2kΩ 0 5 8 0 1Ω 20kΩ 0 5 8 1Ω 200kΩ 0 5 8 10Ω 2MΩ 0 5 8 100Ω 20MΩ 0 5 8 1KΩ 200MΩ 5 0 10 10KΩ Over load protection 250V DC or AC peak value At range 200Ω short circuit the test lead...

Page 4: ...test Value displayed Forward voltage drop of diode Testing condition Forwrd DCA is approx 1mA the backward voltage is approx 3V Value displayed Buzzer sounds the resistance is less than 50 20 Ω Testing condition Open voltage is approx 3V Overload protection DC or AC250V peak value Warning It s forbidden to input voltage value in this range for the sake of safety 2 2 10 Temperature Range Accuracy R...

Page 5: ...3 Application Method 3 1 Description of operating panel 1 LCD unit It displays the numerical value measured with the instrument and its unit 2 Buzzer indicator lamp 3 REL key 4 HOLD B L ...

Page 6: ... RMS Never contact the high voltage circuit measured 3 3 AC Voltage Measurement Insert the black multimeter probe into COM end and the red multimeter probe into VΩHz end Select the knob to a proper ACV range and then connect the test leads crossly to the electric circuit under test Notes Firstly users should select the knob to the highest range if users had no idea about the range of voltage under...

Page 7: ...range and the range switch shall be rotated to a higher level The maximum input current is 200mA or 20A depending on the inserting location of red probe In case of exceeding rated current the fuse will be melted or even the instrument will be damaged 3 6 Resistance measurement Insert the black multimeter probe into COM end and the red multimeter probe into VΩHz end Select the knob to a proper resi...

Page 8: ... 10Vrms but the accuracy is not guaranteed In noise environment you d better use shiel cable to measure a low signal Don t input voltage higher than 250V DC or AC peak value or it may damage the meter Never contact the high voltage circuit measured 3 9 Diode and on off test Insert the black multimeter probe into COM hole and red multimeter probe into VHz hole the polarity of red multimeter pole is...

Page 9: ...eld environment Please clean the outer surface of the instrument with wet fabric and gentle detergent instead of grinding additives and strong solvents like alcohol etc If the instrument is left unused for long term the battery shall be taken out in order to avoid that the instrument is eroded by battery weeping When symbol displays should replace the battery For replacement of fuse please use fus...

Page 10: ...t of current Replace the fuse Big error in display Replace the batteries The specifications are subject to change without notice The content of this manual is regarded as correct error or omits Pls contact with factory We hereby will not be responsible for the accident and damage caused by improper operation The function stated for this User Manual cannot be the Reason of special usage ...