Before the replacement, the test leads must leave the measuring point and ensure there is no any 
signal at the input terminal. 

5.

 

Don’t use other unconfirmed or disapproved battery to replace the battery inside the meter.  

Only the battery of the same model or same electrical specification can be replaced. Before the 
replacement, the test leads must leave the measuring point and ensure there is no any signal at the 
input terminal. 
 
6.

 

When the electrical measurement is made, never let your body gets in touch with the ground 

directly, and don’t touch uncovered metal terminal, output port, lead clamp and etc. where earth 
potential may exist. Dry clothes, rubber shoes, rubber cushion and other insulating material are 
usually used to keep your body insulated against the ground. 

7.

 

Don’t store and use it in the high-temperature, high-humidity, inflammable and strong magnetic 

field environment. 

8.

 

It may do damage to the meter and endanger the operator’s safety if the voltage value beyond 

the permitted ultimate voltage value is measured. The ultimate voltage value permitted for 
measurement is marked on the instrument panel, and never measure the value exceeding the 
standard. Don’t input the ultimate value out of regulation in order to avoid electric shock and the 
damage to the meter. 

9.

 

When the test leads is inserted into the current socket, don’t measure any voltage for fear that 

the meter should be damaged and operator’s safety be endangered. 

10.

 

Don’t try calibrating or repairing the meter. When necessary, only the qualified professional 

personnel who have had special training or gained approval can make it. 

11.

 

During measurement, the requirement of measurement function must be in accordance with 

LCD display. Please be sure to disconnect the line of the test leads with the measured object first 
and ensure there is no any input signal. It is forbidden to switch the function/range selection switch 
during measurement. 

12.

 

When “

” is show on LCD display, please replace battery immediately to ensure the 

measurement precision. 

13.

 

It is not allowed to insert the test leads into the current terminal to measure voltage! 

14.

 

Please don’t change the circuits of the meter freely for fear that the meter be damaged and the 

safety be endangered. 

15.

 

Descriptions of safety symbols: 

 

 

 

Summary of Contents for AX-105

Page 1: ...DIGITAL MULTIMETER AX 105 OPERATION MANUAL...

Page 2: ...r immediately Digital Multimeter 1PC Instruction Manual 1 copy Test Leads 1 pair Temperature Probe K Thermocouple 1 PC AAA 1 5v 7 battereies 2 PCs Holster 1 PC III Safety Considerations The design of...

Page 3: ...ultimate voltage value permitted for measurement is marked on the instrument panel and never measure the value exceeding the standard Don t input the ultimate value out of regulation in order to avoi...

Page 4: ...uty cycle could be selected by pressing this button in AC DC voltage or AC DC current gear 3 2 SELECT Function Switch Press this button the function could switch between DC AC 3 3 REL Relative Value M...

Page 5: ...ssing the HOLD button to turn on the instrument VI Property 1 General Property 1 1 Display LCD 1 2 Max Display 3999 3 counts automatic polarity display and unit display 1 3 Measuring Method Dual integ...

Page 6: ...aution 1 Don t measure voltage over 600V Otherwise ther is a danger of meter being damaged 2 When measuring high voltage special attention should be given to personal safety and avoid your body gettin...

Page 7: ...age value response RMS of sine wave 2 2 3 DCA 1 Insert the black test lead into the COM input terminal and red one into the input terminal Max 400mA or 10A input terminal Max 10A 2 Rotate function swi...

Page 8: ...leads to the tested circuit in serial the tested current value and the current polarity of the point where the red one is connected will be displayed on the screen simultaneously Caution 1 If OL is di...

Page 9: ...ent range limit please select higher range to complete the measurement When measuring the Resistor higher than 1M the instrument will take several seconds to make the reading stable It is normal when...

Page 10: ...the result does not meet the above it means the diode is bad 6 Press SELECT button to select the Continuity measurement mode 7 Connect the meter pens to two points of the tested circuit If the built i...

Page 11: ...e 2 2 8 Frequency F 1 Connect test leads and shielded cable to COM terminals 2 Rotate function switch to Hz gear Connect test leads and the cable to the signal source or the tested load The tested sig...

Page 12: ...put the working end temperature measurement end of thermocouple on the surface or inside the object to be tested Then you can read temperature from the screen and the data is in Centigrade Caution 1...

Page 13: ...batteries and replace them with two new ones Although a 1 5V battery of any standard can be used but in order to lengthen the operation life alkaline batteries should be used 3 Mount the battery door...

Page 14: ...ct and in case readers find any errors and missing parts please contact the manufacturer The Company shall not be held liable for any accidents and hazards resulted from the mal operations by the user...

Reviews: