Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EEA contact address
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2019-12-09
Technical improvements, changes in design, printing- and other errors expected.
Safety advices:
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
SES 5532-19
premium
-line
Programmable
Unicable II Multiswitch
Quick start guide
Technical data:
Type
SES553219
Inputs
Number
5
Frequency range
5…862 MHz @ TERR
250…2350 MHz @ SAT
Level (AGC)
59…94 dBµV
Isolation V | H.
>25 dB
Subscriber ports
Number
2
Supported standards
EN 50494, EN 50607
Tap loss TERR
13 dB
Frequency range (SAT)
950…2150 MHz
User bands
32
Gain SAT Unicable II (SCR/CSS)
25 dB
Gain SAT (Legacy)
10 dB
Output level SAT (SCR/CSS)
84 dBµV
Trunk outputs
Number
5
Through loss TERR
3 dB
Through loss SAT
3 dB
Connectors
Connector type
F
General
Current consumption
500 mA
Equipotential bonding connection
4 mm²
Dimensions (W × H × D) appr.
195 × 145 × 85 mm
Protection class
IP 20
External accessories
Switching power supply
100…240 VAC / 50…60 Hz | 19 VDC/940 mA
Power inserter
5…2400 MHz | 18V/750 mA
Herewith AXING AG declares that the marked products comply with the valid
guidelines.
WEEE Nr. DE26869279 | Electrical and electronic components must not be
disposed of as residual waste, it must be disposed of separately.