Field of application:
The devices are suitable for amplifying and distributing radio and television
signals in the house only! If the device is used for other purposes, no warranty
will be given!
Equipotential bonding and Mounting:
To avoid dangerous overvoltages (attention: risk of fire/death), the devices must be connected to the equipotential bonding according to EN 60728-11.
Use the equipotential bonding connection attached to the device (1).
To connect the outer conductor of the coaxial cable to the equipotential bonding, use e.g. QEW earth connection angles or CFA earth connection blocks at
the input and output of the amplifier.
Use the mounting screws included in the delivery and the mounting holes of the devices (2).
RF Installation:
Connect the inputs of the amplifier to a corresponding antenna/signal
source that is suitable for the input.
Input ANT 1
VHF antenna
Input ANT2/3
UHF antenna
Input BI/FM
VHF I/FM antenna
Input EXT VHF+UHF
e.g.
for CATV connection
Connect the output of the amplifier to the antenna sockets or the
splitters used.
Use screened coaxial cables with F connectors. Suitable cables and plugs
can be found in the current AXING catalogue or at www.axing.com.
Adjustments:
For the inputs ANT 1 to 3, a remote feeding of the connected antenna with
12 V/max. 100 mA can be switched on.
For this, press the buttons (3). The corresponding LED (4) signalizes a
remote current on the input.
Note:
When the 100 mA is exceeded, the green LED changes to red and
the DC supply is switched off.
The inputs ANT1 and 2 can be switched on or off. Set the switches (5) to
the upper position for switching on the antenna.
The channel control (6) can be used to set up to 10 channels.
The level controls (7) can be used to set the level of the 10 channels
independently.
The level controls (8) can be used to set th