background image

State of the art 2021-01-11

 

Observe the safety instructions supplied with the device!
They are also available at the following Internet address:

https://download.axing.com/BAs/Sicherheitshinweise_9sprachig.pdf

 

Use the device only as described in these operating instructions and in 
particular in accordance with the state of the art. 
If the device is used for other purposes, no warranty will be assumed!

Technical improvements, changes in design, printing- and other errors reserved.

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

BVS 14-69P

premium

-line

CATV amplifiers

Operation instructions

Technical data:

Herewith AXING AG declares that the marked products comply with the valid 

guidelines.

WEEE Nr. DE26869279 | Electrical and electronic components must not be 

disposed of as residual waste, it must be disposed of separately.

Typ

BVS 14-69P

EMC

according to EN 50083-2, 

class A

Classification according to 1 TS 140

D(4.4)

Downstream

Frequency range

85…1218 MHz 

Gain

40 dB

Max. output level CSO/CTB 
(CENELEC raster, 41 channels 60 dB IMA)

111 dBµV

Max. output level CSO/CTB 112 channels QAM 
(acc. EN IEC 60728-3-2018-08, flat, BER<1x10

-9

)

106 dBµV

Max. output level CSO/CTB 112 channels QAM 
(acc. EN IEC 60728-3-2018-08, 6 dB Slope, BER<1x10

-9

)

108 dBµV

Attenuation: adjustable in 1 dB steps

0…15 dB

Equalization: adjustable in 1 dB steps

0…15 dB

Attenuation interstage: pluggable with jumpers

0 | 2 | 4 | 6 dB

Equalization interstage: pluggable with jumpers

0 | 2 | 4 | 6 dB

Gain interstage: pluggable with jumpers

40 | 30 dB

Return loss

≥ 18 (-1,5 dB/Okt.)

Noise figure typ.

<7dB

Upstream

Frequency range

5…65 MHz

Gain

30 dB

Attenuation: adjustable in 1 dB steps

0…15 dB

Equalization interstage: pluggable with jumpers

0 | 3 | 6 | 9 dB 

Attenuation interstage: pluggable with jumpers

0 | 6 dB 

RF connectors

Type

F-female

Test port at in-/output

-20 ±2,5 dB/-20 ±1,0 dB

General

Switching power supply

100...240 VAC / 50...60 Hz

Power indicator

LED

Power consumption

14 W

Equipotential bonding connection

4 mm²

Operating temperature range (acc. to EN 60065)

-20…+50°C

Dimensions (W × H × D) appr.

182 × 146 × 71 mm

Protection class

IP 54

Reviews: