axing premium-line BVS 14-66 Operation Instructions Download Page 3

BVS 14-66

premium

-line

CATV Amplifier

Operation Instructions

State of the art 2015-02-27 - Reserving change in design and type - 
We cannot be held liable for printing errors

Manufacturer
AXING AG 
Gewerbehaus Moskau
CH-8262 Ramsen 

EWR contact adress
Bechler GmbH
Am Rebberg 44
D-78239 Rielasingen

Safety advice:

4

Installation and repairs to the equipment may only be carried out by 
technicians observing the current VDE guidelines. No liability will be 
assumed in the case of faulty installation and commissioning.

4

Before opening the equipment pull out the power plug or remove the 
power supply, otherwise there is danger of electrocution. This is also 
valid for cleaning the equipment or working on the connections. 

4

Only use the mains cable connected to the device. Never replace any 
parts or make any modifications on the mains cable. Otherwise there is 
a risk of mortal injury for which we cannot be held liable.

4

Providing that a serviceable fuse exists, the power cord must be pulled 
out before changing the fuse. Defective fuses may only be replaced 
with standard compliant fuses that have the same nominal value.

4

The equipment may only be operated in dry rooms. In humid rooms or 
outdoors there is danger of short-circuit (caution: risk of fire) or 
electrocution.

4

Choose the location of installation or mounting so that the power plug 
can be reached and pulled out of the socket easily in case of danger. 
Choose the location of installation or mounting such that children may 
not play unsupervised near the equipment and its connections. The 
location of installation or mounting must allow a safe installation of all 
cables connected. Power feeding cables as well as feeder lines may not 
be damaged or clamped by objects of any kind. To prevent damage to 
your equipment and to avoid possible peripheral damages, the devices 
foreseen for wall mounting may only be installed on a flat surface.

4

Choose a location of installation or mounting which complies to the 
protection class IP 54.

4

Avoid exposure of the equipment to direct sunlight and to other heat 
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices 
that are equipped with heat sinks or ventilation slots must under no 
circum-stances be covered or blocked. Also ensure for a generous air 
circulation around the equipment. In this way you avoid possible 
damage to the equipment as well as a risk of fire caused by 
overheating. Absolutely avoid that cables come near any source of heat 
(e.g. radioators, other electrical devices, chimney, etc.).

Technical specifications:

KBW classification 

 Class D (4.4)

Downstream

Frequency range  

 85…1006 MHz

Gain 

 40 dB

Attenuation (adjustable in 1 dB steps) 

 15 dB

Slope (adjustable in 1 dB steps) 

 15 dB

Attenuation (Interstage) 

 0/2/4/6 dB 

Equalization (Interstage) 

 0/2/4/6 dB

Output level 

 111 dBµV (CSO/CTB¹)

Noise figure 

 <7 dB

Return loss  

 

³

18 dB (-1,5 dB/Okt.)

Upstream

Frequency range   

 5…65 MHz

Gain 

 30 dB

Attenuation (adjustable in 1 dB steps) 

 15 dB

Attenuation (Interstage) 

 0/6 dB 

Equalization (Interstage) 

 0/3/6/9 dB

Attenuation (Output) 

 0/3/6/9 dB

Noise figure 

 <7 dB

Return loss 

 

³

18 dB (-1,5 dB/Okt.)

RF Connectors 

 F

Test port input, bi-directional 

 -20dB

Test port output, uni-directional 

 -20dB

Dimensions appr. 

 182 × 146 × 71 mm

Switching mode power supply 

  30…65 V~/50...60 Hz

Power consumption 

 14 W

¹CENELEC Raster 41 ch. 60dB IMA

D (4.4) acc. 
KDG 1 TS140