2020-11-13 | Technical improvements, changes in design, printing- and other errors expected.
51
3.9.
CAS
S
imulcrypt (with MKS 1-02)
The setup for the conditional access system requires the installation and configuration of a CAS server, which
generates ECMs and EMMs, among other things. Setting up a CAS server is not described in this document.
To configure the settings for the headend unit, you must have a corresponding licence (see 3.7 on page 45). If
this licence is activated in the headend, the necessary settings can be made under CAS.
Click on CAS SETTINGS.
Several fields and tables for the CAS settings are displayed.
3.9.1.
Global Settings
Enable Simulcrypt
: Enable or disable Simulcrypt (license needed to activate).
Network interface
used for all simulcrypt-related network traffic, option values:
∂
Control (Configuration port)
∂
IPTV (IPTV input)
∂
CAS (CAS port)
The IP address of the port must be configured for EMMG (CAS server), see 3.6.2 on page 38.
EMMG Listening Port:
TCP port configured in EMMG (CAS server) to connect the headend.
3.9.2.
CAS List
The table is used to assign readable names to CAS-IDs in order to be able to assign them more easily in the
following tables.
Add here all connected CA-Systems. Each CA-System is identified by two IDs, the “CA system id” (
CAS ID
) and
“CA subsystem id” (
Sub ID
.
3
Sometimes both values can be seen combined to a single “Super CAS ID”.