background image

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2018-10-08

Technical changes, design modifications, errors and misprints are subject to 

change without prior notice.

Safety advices:

 

Installation and repairs to the equipment may only be carried out by 
technicians observing the current VDE guidelines. No liability will be 
assumed in the case of faulty installation and commissioning.

 

To prevent damage to your equipment and to avoid possible peripheral 
damages, the devices foreseen for wall mounting may only be installed 
on a flat surface.

 

Choose the location of installation or mounting such that children may 
not play unsupervised near the equipment and its connections. The 
location of installation or mounting must allow a safe installation of all 
cables connected. The mains cable as well as feeder lines may not be 
damaged or clamped by objects of any kind. 

 

Choose the location of installation or mounting so that under no 
circumstances liquids or objects can get into the equipment (e.g. 
condensation, water coming from leaking roofs or flowing water, etc.).

 

Avoid exposure of the equipment to direct sunlight and to other heat 
sources (e. g. radiators. other electrical devices, chimney, etc.). Absolutely 
avoid that cables come near any source of heat (e.g. radioators, other 
electrical devices, chimney, etc.).

SPU 81-00 | SPU 81-02

basic

-line

8 in 1 | 2 × 8 in 1
DiSEqC switches

Operation instructions

Technical data:

Article

SPU 81-00

SPU 81-02

Type

8 in 1

2 × 8 in 1

Switching criteria

Position  + Option  + Uncommi DiseqC 1.2 „drive to position x“ (6Bh)

Supported DiSEqC level of the SA

T receiver

1.1 | 2.1 | 1.2 | 2.2

Frequency range (upstream | 

TERR | SA

T)

– | – | 950…2200 MHz

Number of inputs

8

2 × 8

Subscriber ports

1

2

Through loss SA

T

typ

. 2,5 dB

Isolation between LNBs

≥ 30 dB

Ambient temperature range (acc.

 to EN 60065)

-20…+50°C

Dimensions (W × H × D) appr

.

150 × 110 × 30

155 × 110 × 50

DiSEqC switching criteria:

Position

Option

Uncommitted_1

drive to position x (6Bh)

= extension of 2 LNBs

= extension of 3-4 LNBs

= extension of 5-8 LNBs

= motor driving comand DiSEqC 1.2

Herewith AXING AG declares that the marked products comply with the valid 

guidelines. You can call up the complete EU declaration of conformity for 

download by entering the article in the search field at www.axing.com.

WEEE Nr. DE26869279 | Electrical and electronic components must not be 

disposed of as residual waste, it must be disposed of separately.

Reviews: