AVM 1-02 | AVM 2-01/-02
Audio/video modulators
Operation Instructions
Safety advice:
4
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
4
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
4
Use only the plug-in power supply unit included in the delivery scope!
By no means is it allowed to replace any parts of the power supply unit
or to make modifications. Otherwise, there is a risk of mortal injury for
which we cannot be held liable.
4
Providing that a serviceable fuse exists, the power cord must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
4
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
4
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped by objects of any kind. To prevent damage to
your equipment and to avoid possible peripheral damages, the devices
foreseen for wall mounting may only be installed on a flat surface.
4
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
4
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
Technical specifications:
WEEE Nr.
DE14023300
Your device is marked with the WEEE symbol (Waste Electronics
and Electrical Equipment). This means that the electrical and
electronic components must not be disposed of as residual waste.
Used electrical and electronic components must be disposed of
separately.
Technical Data:
Frequency range
175…862 MHz
Channels
5…12, S11…S41, 21…69
Gain riple
± 1,0 dB
Output level
70dBµV
HF Output impedance
75 Ohm
Video input impedance
75 Ohm
Audio input level
10 kOhm
Video input level
1 V
SS
Audio input level
1 V
SS
RF Connectors (output)
F-female
AVM 1-02
Connector video
RCA/Cinch
Connector audio (mono)
RCA/Cinch
Current consumption
200 mA
Power supply
230 V~/50 Hz 6 V=/500 mA
Dimensions appr. (L x W x H)
105 x 91 x 36 mm
AVM 2-01
Connector video
RCA/Cinch
Connectors audio (stereo)
RCA/Cinch
RF Connectors (input)
Current consumption
250 mA
Power supply
230 V~/50 Hz 12 V=/250 mA
IEC-female
Dimensions appr. (L x W x H)
225 x 91 x 36 mm
AVM 2-02
same data like AVM 2-02
Connectors audio/video
SCART
Delivery
AVM audio/video modulator
AV connecting cable (AVM 1-02/2-01) SCART cable, 1 m (AVM 2-02)
Power supply 230 V~/50 Hz, CFA 10-00 adapter (F male - IEC male)
State of the art
6-08-22 Technical changes, design modifications,
201
errors and misprints are subject to change without prior notice.
Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
78239 Rielasingen