How the verifier works

The verification begins with capturing an image which includes one or more 

barcodes. Having captured this image, the verifier is then asked to decode any 

barcodes it can find in the image. This is a two stage process, which is started by 

clicking on the green arrow icon (or pressing one of the buttons on the verifier) to 

start the image capture, and then by clicking on the decode command icon (the two 

turning arrows) or by pressing one of the buttons a second time.

The image that has been captured and decoded can be saved as a .png file, and 

this can be re-verified at any later time. This is useful when the image contains 

more than one barcode. The software allows the creation of verification reports for 

each barcode that appears in the image, and the user simply clicks on the relevant 

barcode for which a report is required.

More details about this process, saving image files, and saving verification reports 

are explained later on in this user guide.

www.axicon.com

Page 6 of 28

Axicon Auto ID Limited  |  15000 series verifier user guide | June 2017

Summary of Contents for 15000 series

Page 1: ...CODE EXPERTS Church Road Weston on the Green Oxfordshire OX25 3QP UK Tel 44 0 1869 351155 Email sales axicon com Web www axicon com user guide Axicon 15000 series 2D linear barcode verifier Industry P...

Page 2: ...Page 2 of 28 Axicon Auto ID Limited 15000 series verifier user guide June 2017 www axicon com...

Page 3: ...s 13 2D matrix codes 18 Several barcodes in field of view 19 Saving and printing 20 Disclaimer 21 Software licence agreement 22 Warranty 24 Service contract 25 Annual service 26 Certificate of conform...

Page 4: ...codes will typically be too large to be read by this verifier Linear barcodes EAN 8 EAN 13 UPC A UPC E Code 39 Code 93 Code 128 Codeabar ITF MSI Plessey 2D barcodes GS1 Data Matrix GS1 QR codes Other...

Page 5: ...drive and the Install program should start automatically If it does not run Setup exe When the software has been successfully installed leave the CD in the drive so that the USB driver will be instal...

Page 6: ...ows or by pressing one of the buttons a second time The image that has been captured and decoded can be saved as a png file and this can be re verified at any later time This is useful when the image...

Page 7: ...hown below and this will appear when the software is launched The window has four main areas and these are explained below Double click on the Axicon Camera Verifier icon The first window will open an...

Page 8: ...d icons Quit the application or use Ctrl Q Load a saved barcode image or use Ctrl O Save the current image and verification report or use Ctrl S Start collecting barcode images in the field of view or...

Page 9: ...fied was scanned by the verifier The Details tab provides a summary of the results of the verification The ISO tab will include details of all the separate parameters defined by ISO IEC for the partic...

Page 10: ...13 barcode at the top left hand side of card so that it appears in the Axicon Camera verifier window as shown below Start the image capture process by clicking on the green arrow icon This will change...

Page 11: ...ess one of the buttons on the verifier both buttons perform the same function The verifier will draw a purple box around each of barcodes it has found and automatically select the first barcode to dec...

Page 12: ...To get more information about the grading of any of the particular parameters you can click on the relevant parameter The verifier will then indicate where the scan lines were taken and if relevant wh...

Page 13: ...e tab allows you to change the colours used for Fail Warning and Pass choose the language and switch between metric or imperial units of measurement Plugins The Plugins tab can be used to select data...

Page 14: ...The options are as follows Autosave records will be automatically saved to provide a complete audit trail of verifications performed The Autosave Directory name should be set by the user If Enable is...

Page 15: ...s are both ticked the file name will automatically be created using the decoded number followed by the date and time If Save as box is ticked a dialogue box will appear and you can enter a filename If...

Page 16: ...ually it could be information about the barcode such as the substrate or print process or details about the operator the department or the site Multiple questions can be entered if desired To set up t...

Page 17: ...ally saved with it When loading a pre saved scan file for which User Data has been attached you simply need to load the scan file and re verify the code using the Search for all barcodes icon and then...

Page 18: ...e individual parameter the reason for any data content error is displayed If required the Data Content box can be stretched vertically to show more information just hover over the top edge of the box...

Page 19: ...ode will be surrounded by a purple or blue box The blue box indicates which symbol s results are being shown on the right hand side of the Axicon Camera Verifier window To change to the other barcode...

Page 20: ...successful decode of a barcode the results can be saved to a file in special form of png format This is done by using the File Save as function These results can be reviewed at some later stage and s...

Page 21: ...Verifier can accept any liability for any loss or damage consequential or otherwise which may be caused by use of this Verifier If the Verifier or any part of it is defective in any way or in some ot...

Page 22: ...ke copies of the software for archival purposes or when copying is an essential step in its use You must reproduce all copyright notices in the original software on all copies You may not copy the sof...

Page 23: ...it is suitable for your needs Neither Axicon Auto ID Limited nor the vendor of this verifier can accept any liability for any loss or damage consequential or otherwise which may be caused by its use...

Page 24: ...additional sum for its replacement Axicon s standard repair turnaround time is 7 10 working days This standard warranty does not include the provision of a loan unit Loan units can be supplied on requ...

Page 25: ...barcode quality in accordance with the requirements of ISO IEC 15426 1 and ISO IEC 15426 2 The service contract will also extend the warranty beyond two years so that if it breaks down all parts and...

Page 26: ...st version of the software on CD together with a new calibration sheet and a new user guide that will include the new certificate of ISO IEC conformance You will then need to calibrate the verifier be...

Page 27: ...ent when used with the latest verifier software and configured appropriately has the features to meet the requirements of the United States Food and Drug Administration regulation Title 21 CFR Part 11...

Page 28: ...1869 351 155 Fax 44 0 1869 351 205 Email info axicon com Website www axicon com As Axicon continually improves its products their specifications and features are subject to change without notice All...

Reviews: