AX010 Series Turntables
AX010
‐
MANUAL
|
5
Installation and Start-Up (Cont.)
5.
Place
the
unit
in
the
desired
loca on
on
a
clean,
level,
fl
at
fl
oor.
a.
Sweep
the
fl
oor
area
to
remove
dirt
and
debris.
b.
The
fl
oor
must
be
level
and
fl
at
within
±1/8”
over
a
10’
span.
Floor
undula ons
outside
this
speci
fi
ca on
may
impact
the
opera on
of
the
turntable
and
should
be
remedied.
The
turntable
base
needs
to
be
fully
supported
underneath
to
transfer
the
loading.
c.
The
fl
oor
must
be
a
concrete
surface
or
equivalent
that
is
capable
of
suppor ng
the
load
of
the
turntable
plus
the
load
of
the
product.
6.
Drill
the
fl
oor
at
the
hole
loca ons
on
the
outer
edge
of
the
turntable
base
plate.
7.
Install
1”
diameter
concrete
anchors
(epoxy
stud
anchors
are
preferred
in
concrete)
or
suitable
equivalent
to
secure
the
turntable
base
to
the
fl
oor.
There
are
16
holes.
8.
If
equipped,
posi on
the
control
stand
in
the
desired
loca on
and
lag
to
the
fl
oor
using
suitable
anchors.
9.
Install
electrical
control
lines
to
motor,
brake,
and
encoder.
Connec ons
are
all
located
on
the
drive
motor.
10.
Connect
the
480
volt
electrical
supply
line
to
the
control
stand
enclosure.
III. Specifications
Model
Diameter
Capacity (lbs.)
Height
Speed
Shipping
Weight
Electrical
Supply
AX010
‐
048
48
in.
150,000
30
⅝
in.
0
–
1
RPM
2,500
lbs.
480
V,
3
phase
AX010
‐
060
60
in.
150,000
30
⅝
in.
0
–
1
RPM
3,500
lbs.
480
V,
3
phase
AX010
‐
072
72
in.
150,000
30
⅝
in.
0
–
1
RPM
4,200
lbs.
480
V,
3
phase
AX010
‐
084
84
in.
150,000
30
⅝
in.
0
–
1
RPM
5,000
lbs.
480
V,
3
phase
AX010
‐
096
96
in.
125,000
30
⅝
in.
0
–
1
RPM
5,800
lbs.
480
V,
3
phase
AX010
‐
108
108
in.
100,000
30
⅝
in.
0
–
1
RPM
6,600
lbs.
480
V,
3
phase
AX010
‐
120
120
in.
100,000
30
⅝
in.
0
–
1
RPM
7,400
lbs.
480
V,
3
phase
Summary of Contents for AX010 Series