          L1-Series User’s Manual 
          MKTF-258 

RUBBER  SEAL  THAT  PROTRUDES  ON  ONE  SIDE  OF  THE  MEMBRANE  AND  IS 
ALWAYS  ON  THE  FEED  SIDE  OF  THE  MEMBRANE  ELEMENT.
SYSTEMS  THE  BRINE  SEAL  SHOULD  BE  ON  THE  RIGHT
HOUSING.    

              

 

1.  Remove membrane element from the

housing.  Long  nose  pliers  may  be  necessary  to  pull  the  old  membrane 
element out of the membrane element housing.

 

2.  Lubricate  the  brine  seal 

such as Dow Corning® 111.

 

3.  Install membrane through the right side (feed water) of the membrane housing 

with brine seal located on the feed water side.

 

4.  With  a  smooth  and  constant  motion,  push  the  membrane  element  into  the 

housing  so the brine  seal  enters  the  housing  without  coming  out of  the brine 
seal groove.  

 

5.  Re-install the end plug 

end  cap,  while  pushing  it  onto  the  housing.  Ensure  that  you  do  not  pinch  or 
fatigue any o-rings while re
the outer diameter of the plug is flush with the outer diameter
vessel. 

 

6.  Insert the two half-moon retaining disks until they are

Subsequently fasten using a #5 Allen wrench

 

 

7.  Reconnect any fittings that may have been disconnected when the membrane 

pressure vessels were disassembled.

 

8.  To  Start-Up  the  system,  please  refer  to  the  Initial  Start

manual.  

    CAUTION:  WET  MEMBRANES  ARE  SHIPPED  IN  A  PRESERVATIVE 

SOLUTION.  THE  MEMBRANES  MUST  BE  FLUSHED  FOR  AT  LEAST  30 
MINUTES  TO  REMOVE  THE  PRESERVATIVE  FROM  THE  MEMBRANE.  
DISCARD  ALL  OF  THE  PERMEATE,  WHICH  IS  PRODUCED  DURING  THE 
FLUSH PERIOD. 

13 

RUBBER  SEAL  THAT  PROTRUDES  ON  ONE  SIDE  OF  THE  MEMBRANE  AND  IS 
ALWAYS  ON  THE  FEED  SIDE  OF  THE  MEMBRANE  ELEMENT.  FOR  L1

BRINE  SEAL  SHOULD  BE  ON  THE  RIGHT  SIDE  OF  THE  MEMBRANE 

Remove membrane element from the right (feed water) side of the membrane
housing.  Long  nose  pliers  may  be  necessary  to  pull  the  old  membrane 

t of the membrane element housing. 

Lubricate  the  brine  seal  and  o-rings  with  a  non-petroleum  based  lubricant, 
such as Dow Corning® 111.  Do not use a petroleum-based lubricant.

Install membrane through the right side (feed water) of the membrane housing 
with brine seal located on the feed water side. 

With  a  smooth  and  constant  motion,  push  the  membrane  element  into  the 
housing  so the brine  seal  enters  the  housing  without  coming  out of  the brine 

end plug (6, Figure 1.A) on the right side by gently twisting the 

while  pushing  it  onto  the  housing.  Ensure  that  you  do  not  pinch  or 

rings while re-installing the end plug. Push the end plug on until 

the outer diameter of the plug is flush with the outer diameter of the pressure 

moon retaining disks until they are fully seated. 

Subsequently fasten using a #5 Allen wrench. 

Reconnect any fittings that may have been disconnected when the membrane 
pressure vessels were disassembled. 

Up  the  system,  please  refer  to  the  Initial  Start-Up  section  of  this 

CAUTION:  WET  MEMBRANES  ARE  SHIPPED  IN  A  PRESERVATIVE 

SOLUTION.  THE  MEMBRANES  MUST  BE  FLUSHED  FOR  AT  LEAST  30 
MINUTES  TO  REMOVE  THE  PRESERVATIVE  FROM  THE  MEMBRANE.  

SCARD  ALL  OF  THE  PERMEATE,  WHICH  IS  PRODUCED  DURING  THE 

9/14

 

RUBBER  SEAL  THAT  PROTRUDES  ON  ONE  SIDE  OF  THE  MEMBRANE  AND  IS 

L1  SERIES  RO 

SIDE  OF  THE  MEMBRANE 

the membrane 

housing.  Long  nose  pliers  may  be  necessary  to  pull  the  old  membrane 

petroleum  based  lubricant, 

based lubricant. 

Install membrane through the right side (feed water) of the membrane housing 

With  a  smooth  and  constant  motion,  push  the  membrane  element  into  the 
housing  so the brine  seal  enters  the  housing  without  coming  out of  the brine 

by gently twisting the 

while  pushing  it  onto  the  housing.  Ensure  that  you  do  not  pinch  or 

installing the end plug. Push the end plug on until 

of the pressure 

fully seated. 

Reconnect any fittings that may have been disconnected when the membrane 

Up  section  of  this 

CAUTION:  WET  MEMBRANES  ARE  SHIPPED  IN  A  PRESERVATIVE 

SOLUTION.  THE  MEMBRANES  MUST  BE  FLUSHED  FOR  AT  LEAST  30 
MINUTES  TO  REMOVE  THE  PRESERVATIVE  FROM  THE  MEMBRANE.  

SCARD  ALL  OF  THE  PERMEATE,  WHICH  IS  PRODUCED  DURING  THE 

Summary of Contents for L1-Series

Page 1: ...Membrane System User s Manual L1 Series...

Page 2: ...L1 Series User s Manual MKTF 258 2 9 14 This Page Left Blank...

Page 3: ...BRANE INSTALLATION REMOVAL AND REPLACEMENT 12 OPERATION DO S AND DON TS 14 SPECIFICATIONS 15 OPERATION AND MAINTENANCE 16 PREPARING UNIT FOR STORAGE OR SHIPMENT 17 REVERSE OSMOSIS TROUBLESHOOTING 18 T...

Page 4: ...details vital to the sustained performance of your If your system is altered at the site of operation or if the feed water conditions consult your local dealer or distributor for assistance NOTE IN O...

Page 5: ...THAT ARE USED TO IDENTIFY CONDITIONS OR PRACTICES THAT COULD RESULT IN EQUIPMENT OR OTHER PROPERTY DAMAGE WARNING INDICATES STATEMENTS THAT ARE USED TO IDENTIFY CONDITIONS OR PRACTICES THAT COULD RES...

Page 6: ...VOID THE MANUFACTURER S WARRANTY OPERATING LIMITS Operating Parameters Feed Temperature 40 85 F System Inlet Pressure 45 85 PSIG Maximum Operating Pressure 77 F 120 PSIG Nominal If any of the feed wat...

Page 7: ...s do not pass through the membrane To calculate the rejection use the following formula Rejection Feed TDS Product TDS Feed TDS x 100 Example 98 5 550 8 25 550 x 100 NOTE ALL TDS FIGURES MUST BE EXPRE...

Page 8: ...to an incoming water source The minimum water pressure should be at least 30 psi The system s minimum operating pressure is 80 PSI but the optimum operating pressure is 100 psi NOTE DO NOT OPERATE AT...

Page 9: ...t water reaches your desired level Use any TDS or Conductivity meter to monitor the product water quality A minimum quality of 96 NaCl rejection is recommended NOTE ANY CHLORINE EXPOSURE WILL DAMAGE T...

Page 10: ...RANE ELEMENTS L1 Series Reverse Osmosis Systems equipped with Thin Film Composite TFC HF4 Extra Low Energy membranes unless otherwise specified General membrane element performance characteristics are...

Page 11: ...L1 Series User s Manual MKTF 258 11 9 14 SYSTEM IDENTIFICATION...

Page 12: ...the end plug should then freely slide out of the pressure vessel 2 Remove the membrane bag containing the membrane element from the shipping box The membrane should be contained within a plastic oxyge...

Page 13: ...uch as Dow Corning 111 Do not use a petroleum based lubricant Install membrane through the right side feed water of the membrane housing with brine seal located on the feed water side With a smooth an...

Page 14: ...itor the system and keep a daily log Run the system as much as possible on a continuous basis Always feed the pump with filtered water DON T Permit chlorine to enter membrane housing with the feed wat...

Page 15: ...L1 Series User s Manual MKTF 258 15 9 14 SPECIFICATIONS...

Page 16: ...e may need to be replaced 3 It is suggested that a hand held TDS digital meter is used once per week to monitor the water quality NOTE IF THE TDS OF THE FEED WATER EXCEEDS 1000 PPM A LARGER FLOW RESTR...

Page 17: ...solution in such a way that the remaining air in the system is minimized after the recirculation is completed 2 Check the pH once a week When the pH becomes 3 or lower change the preservation solutio...

Page 18: ...mperature See temperature correction sheet Poor permeate quality Low operating pressure See low inlet pressure Damage product tube o rings Inspect and or replace Damaged or oxidized membrane Replace m...

Page 19: ...of the rated production after correcting the feed water temperatures above or below 77 F Check your permeate flow meter to determine the permeate flow rate NOTE TO DETERMINE THE TEMPERATURE CORRECTIO...

Page 20: ...w at 77 F by the temperature correction factor The result is the permeate flow at the desired temperature See example on the next page If a system is rated to produce 5 gpm of permeate water 77 F the...

Page 21: ...If service assistance is required please complete the following process Contact your local dealer or distributor Prior to making the call have the following information available system installation...

Page 22: ...____________________ System Serial ____________________ DATE TIME HOUR OF OPERATION FILTER INLET PRESSURE PSI FILTER OUTLET PRESSURE PSI CONCENTRATE PRESSURE PSI PUMP DISCHARGE PRESSURE PSI FEED FLOW...

Page 23: ...L1 Series User s Manual MKTF 258 23 9 14 SYSTEM DRAWING...

Page 24: ...L1 Series User s Manual MKTF 258 24 9 14 L1 300 FLOW DIAGRAM...

Page 25: ...L1 Series User s Manual MKTF 258 L1 SERIES ELECTRICAL 25 ELECTRICAL SCHEMATIC 110V 60HZ 9 14 110V 60HZ...

Page 26: ...L1 Series User s Manual MKTF 258 L1 SERIES ELECTRICAL 26 ELECTRICAL SCHEMATIC 220V 50HZ 9 14 0HZ...

Page 27: ...ty does not cover disposable items such as fuses o rings regeneration materials chemicals or other such disposable items which must be replaced periodically under the normal and foreseeable operating...

Page 28: ...r other payment guarantee prior to shipment If the returned part is found to have been misused or abused or the defective part is not received by AXEON within thirty 30 days the Customer will be invoi...

Page 29: ...STOMER MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION THE PARTIES RECOGNIZE AND AGREE THAT IN ALL RESPECTS THE LAWS OF THE STATE OF CALIFORNIA SHALL APPLY TO AND SHALL GOVERN...

Reviews: