Rev 1.0 

Key Function

 

1.In normal display,The key function is call out setting group 
2.In parameter setting page,The key function is data Enter , and goto next page 

Key Function

 

1.In normal display,The key function is call out alarm value setting page 
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can 
press shift key into setting procedure,The display is lock parameter data,this time must let off key 
about 0.2 sec,press again,the cursor(twinkle express)is cycle moving left. (Key Response about 0.2 
sec) 

Key Function

 

1.In normal display,The key function is call out adjustment display scale page 
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can   
press up key into setting procedure,The display is lock parameter data,this time must let off key 
about 0.2 sec,press again,the parameter data will increment. (Key Response about 0.2 sec)   

Key Function

 

1.In normal display,The key function is call out adjustment analog output ZERO&SPAN page 
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can 
press down key into setting procedure,The display is lock parameter data,this time must let off key 
about 0.2 sec,press again the parameter data will decrement. (Key Response about 0.2 sec)   

&

Key Function

 

 

In setting group or setting page press 

&

 key return normal display,but if in setting page the 

 

modify data will be lost   

No Key in anything 

In setting group or setting page no key in anything about 2 minutes,return normal display,but if in   
Setting page the modify data will be lost 

Step 

Parameter Mark Description  Parameter Mark  Operation Manual 

Normal display 



 

Press 

/FUNC key into P.COD setting page

 



 

P.COD(Pass code input page) 
 



 

1.Key in 5 digit pass code with 

or

or

key

  

 

2.Press 

key,the pass code is right into setting group , otherwise 

 

  return normal display 

SYS(System setting group) 



 

ROP(Alarm setting group) 



 

AOP(Analog output setting           
group) 



 

DOP(Communication setting 
group) 



 

1.

 

Select setting group with 

 key

 

2.

 

Press

key into setting page of selection setting group

 

 

SYS(System setting group) 



 

Press

key decide SYS setting group , press

key into Dp setting 

page 



 

4-1 

DP(Decimal Point setting 
page) 
Value on EEPROM reset=0 

 

1.

 

Decide decimal point position with

or

 key (0 to 4)

 

 

2.

 

Press

key enter data and into TYPE setting page

 



 

4-2 

TYPE(Input Type setting 
page) Value on EEPROM 
reset=1U2D 



 

1.Decide input type with

or

key (1U2D/1P2D/1A2B)

 

 

2.Press

key enter data and into CODE settin

g page 



 

4-3 

CODE(Pass Code setting 
page) 
Value on EEPROM reset=0 



 

1.Decide pass code with 

or

or

key(0~99999)

  

 

2.Press

key enter data and into LOCK setting page

 



 

4-4 

LOCK(Panel Lock setting 
page) 
Value on EEPROM reset=NO 



 

1.Decide panel lock with

or

key(NO or YES)

 

 

2.Press

key enter data and return SYS setting group

 

 

ROP(Alarm setting group) 



 

Press

key decide ROP setting group,press

key into ACT1 setting 

page 



 

5-1 

ACT1(Alarm Active 1 setting 
page ) 
Value on EEPROM reset=HI 



 

1.Decide active 1 with 

or

key(HI or LO)

 

 

2.Press

key enter data and into ACT2 setting page

 



 

5-2 

ACT2(Alarm Active 2 setting 
page ) 
Value on EEPROM reset=HI 



 

1.Decide active 2 with 

or

key(HI or LO)

 

 

2.Press

key enter data and into HYS1 

setting page 



 

5-3 

HYS1(Alarm Hysteresis 1 
setting page) 
Value on EEPROM reset=0 



 

1.Decide Hysteresis 1 with

or

or

key(0~999)

  

 

2.Press

key enter data and into HYS2 setting page

 



 

5-4 

HYS2(Alarm Hysteresis 2 
setting page) 
Value on EEPROM reset=0 



 

1.Decide Hysteresis 1 with

or

or

key(0~999)

  

 

2.Press

key enter data and into DEL1 setting page

 