SR-Series Manual
2. Press the key to turn the scale on.
3. Once the LCD shows “8888” tap the
key five
times until a random code displays.
4. Press
again. The display will flash “CAL” followed
by the required calibration weight (see chart).
5. Add the required weight to the hook. The display will
show pass and return to normal weighing mode.
6. Remove the weight and press and hold the key to
turn the scale off. Calibration is complete!
IX. Troubleshooting
•
Problem:
Scale will not turn on
•
Solution:
Check the batteries
•
Problem:
Display will not stabilize
•
Solution:
Make sure the weight is stable on the
hook and not shaking or swinging
•
Problem:
Displayed weight is inaccurate
•
Solution:
Perform a calibration adjustment
X. Error Codes
1. OUTZ
- Zero setting has shifted. Perform calibration
adjustment. If the problem persists, the load cell may
be permanently damaged due to overloading.
2. EEEEE
- Maximum capacity exceeded. Remove the
extra weight to avoid damaging the load cell.
3. LLLLL
- Load cell has been overloaded.