SC-Series Manual

III. Power

Low batteries can cause inaccuracy in digital scales. If 

you are experiencing issues with your scale, first try new 

batteries. Most times, this will solve the problem.

1. 

Before using the scale for the first time, check 

the battery compartment and remove any plastic 

insulation strips or packaging that may be in place to 

prevent battery drainage during shipping/storage.

2.  If you are replacing the batteries, make sure the 

positive and negative contacts are properly aligned.

3.  Only use the included adapter when plugging the 

scale into AC power. (SC-501A & SC-2KGA only)

IV. Operation

1. 

Place the scale on a flat, level surface and press the 

ON/OFF 

key to turn the scale on.

2.  Once the start-up process completes and the scale 

goes to zero you are ready to weigh.

3.  Place the quantity to be weighed onto the weighing 

platform.

4.  Wait a couple seconds for the display to stabilize 

before taking a weight reading.

5.  To turn the scale OFF, press the 

ON/OFF 

key again.

V.  Changing the Unit of Measure

1.  Press the 

MODE

 key to change the scales displayed 

unit of measure.

2.  If the scale is turned off then back on, it will default 

to the last unit used.

• 

SC-501/A Units:

 g (gram)   oz (ounce)   ct (carat) 

 gn (grain)

Summary of Contents for SC-501

Page 1: ...American Weigh Scales SC 501 SC 501A 500g x 0 01g SC 2KG SC 2KGA 2000g x 0 1g User Manual SC Series Copyright 2011 American Weigh Scales Inc All rights reserved Rev 2 0...

Page 2: ...30 60 seconds before performing calibration Store your scale in a clean dry location Dust dirt and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction Avo...

Page 3: ...AA Batteries x2 4 AC Adapter II Key Description 1 ON OFF key Press to turn the scale ON or OFF 2 MODE key Changes the displayed weighing unit 3 TARE key Re zeros the scale Used to remove the weight of...

Page 4: ...y use the included adapter when plugging the scale into AC power SC 501A SC 2KGA only IV Operation 1 Place the scale on a flat level surface and press the ON OFF key to turn the scale on 2 Once the st...

Page 5: ...container with the quantity to be weighed The display will show the net weight of the contents 4 To return to normal weight display gross weight remove any items from the weighing platform and press t...

Page 6: ...The display will flash CAL followed by the first required calibration weight 4 Place the first required weight on the platform 5 Once the first weight is confirmed the display will flash the second r...

Page 7: ...stment must be performed with the weights listed in the chart on the previous page or inaccuracy will occur X Error Codes 1 OUTZ or OUE2 Zero point has drifted out of the acceptable range Try to perfo...

Page 8: ...g 0 3g Power 2 x 1 5V AAA Alkaline or AC Adapter 5V 500mA Auto Off Time 90 Seconds of Non Use Disabled when using AC Adapter Dimensions 4 1 x 5 0 x 0 7 in Platform Dimensions 4 0 x 4 0 in Warranty 10...

Reviews: