V1.3
18
Lightning protection
YES
Conversion efficiency
≥92%
Static loss
<
5W
Ambient temperature
-20℃
~
+40℃
Humidity
0~90%, No condensing
Noise
≤65dB
Cooling mode
Forced air cooling
Installation mode
Wall-mounted
Cover protection class
IP42
Product dimension
(W*H*D)
360×440×191mm
300×375×145mm
Product net weight
13kg
10kg
Dump load dimension
(W*H*D)
400×390×210mm
Dump load net weight
12kg
Note: Part of parameters can be adjusted according to customer’s specific demand.
5-10kW
Model
WW50-48-240
WW50-120-240 WW50-240-240 WW100-240-240
Type
Buck
Boost
Wind Turbine Input
Rated input power
5kW
10kW
Rated input voltage
280Vdc
Input voltage range
0~320Vdc
Start charge voltage
60Vdc (factory default,40Vdc~320Vdc settable)
Rated input current
21A
42A
Brake by hand
Keep press the button for 5s to unload completely, and then recover by hand.
Switch “ON” the brake switch