1010 Professional Transducer Display
Quick Start
Page 10
Advanced Witness Systems Ltd
1010 Professional Transducer Display Operating Manual
When the reading is within the Lower and Upper limits the green
LED’s will light up. If the torque reading is at or above the “
Upper
limit
” the red LED’s will light up. If the torque reading is at or below
the “
Lower limit
” the yellow LED’s will light up.
Additionally in Peak and 1
st
Peak modes the Digits on the display
will match the colour of the limit indicating LED’s.
MAXIMUM TORQUE LIMIT
The yellow ribbon graph at the top of the display shows the
percentage of torque applied compared to full scale torque value of
the transducer. If the bar is flashing the maximum torque range of
the transducer has been exceeded.
Warning: do not exceed 110% of the MAXIMUM TORQUE
RANGE doing so could permanently damage the Transducer
and void its warranty.
EXAMPLE READING SHOWING MODE SELECTION
MAXIMUM TORQUE LIMIT
MODES
The PTD works in three different modes. Each mode has a
different use and they can be easily switched between. The display
will show which mode is currently selected by a pictographic graph
representing that mode (See Page 6).
RUN:
Run mode continually displays the actual torque applied to
the transducer. This mode as an instance can be used for reading
torque directly, to check the calibration of dial and electronic types
of indicating torque tools or to calibrate a transducer