background image

 
 
 
 
 
 
 
 
 
 

 

  

  

  

  

 O

P

E

R

A

T

IN

G

 M

A

N

U

A

L

 

 

PROFESSIONAL TRANSDUCER 

DISPLAY 

Advanced Witness Systems Ltd 

1010

1010

1010

1010    

Summary of Contents for 1010 Series

Page 1: ...OPERATING MANUAL PROFESSIONAL TRANSDUCER DISPLAY Advanced Witness Systems Ltd 1010 1010 1010 1010 ...

Page 2: ...1010 Professional Transducer Display Page 2 Advanced Witness Systems Ltd 1010 Professional Transducer Display Operating Manual AWS Ltd Fifth Print 2020 ...

Page 3: ...ge 3 Advanced Witness Systems Ltd 1010 Professional Transducer Display Operating Manual Professional Transducer Display Operating Manual Model No 1010 INDEX Description Page 4 Specification Page 6 Quick Start Guide Page 8 Calibration Guide Page 13 ...

Page 4: ...ion units of measure and limits making for easy operation of the instrument When limits are selected two columns of LED s either side of the screen show the state of the limits in conjunction with colour change of the digits on the display as the measurements are made On the battery powered version 1010B battery charge state and charging indication are shown at switch on and during operation Batte...

Page 5: ...0B or 1010H 1x Mains power Supply with UK and EU mains connections 1x Operating Manual 1x Display Stand Optional Mil C Connector to transducer D sub 9 Auxiliary Connector DC power connector for recharging internal batteries 1010B H only Pushbutton for turning PTD on 1010B 1010 H Only Red Yellow and Green LED S indicate Torque Value Soft key buttons function changes dependant on screen On Off switc...

Page 6: ...echargeable batteries The display contains a heater enabling it to be used at subzero temperatures Rated to IP 67 Unit Is Handheld Ergonomically Designed and Lightweight Wide Dynamic Response flat to 1 kHz in all modes Multi Coloured dual LED Limit State Indication with additional digit colour change when limits selected Modes Run Peak and 1st Peak with optional limit selection Modes selected by s...

Page 7: ...uto power off function extends life of the display Supplied with 12V DC mains power supply with UK and EU mains connections Accuracy Better than 1 of reading from 4 to 100 F S D when used with AWS Intelligent In line Torque Transducers Display is accurate to 0 1cNm dependant on units selected Data Output Female D sub 9 Auxiliary Connector Transducer Connection Mil C 26482 series 6 pin Shell size 1...

Page 8: ...the unit on To turn off the 1010M switch the switch on the upper casing to the Off position After switch on the screen will show the range of the transducer attached to the PTD If no transducer is connected then it will show Not Found 1010B H Press and hold the push button on the upper 1010B H case to turn the unit on The 1010B H can be turned off by pressing and holding the far left soft key The ...

Page 9: ... value and setting the limits Selected units can be changed from the main screen by pressing back twice and reselecting a new unit UNIT SELECTION UPPER LIMIT SET LIMITS Set the target torque limit to the required setting see key chart on page 12 on how to use buttons for limit value setting Set the upper limit to the maximum permissible torque reading Please note this is limited to 110 of the tran...

Page 10: ...applied compared to full scale torque value of the transducer If the bar is flashing the maximum torque range of the transducer has been exceeded Warning do not exceed 110 of the MAXIMUM TORQUE RANGE doing so could permanently damage the Transducer and void its warranty EXAMPLE READING SHOWING MODE SELECTION MAXIMUM TORQUE LIMIT MODES The PTD works in three different modes Each mode has a differen...

Page 11: ...ious set up then the peak reading will be displayed for approximately 3 seconds before being reset PEAK Peak mode will display the maximum torque value that was detected Reducing the torque will display the highest detected peak torque This can be used to check the calibration of cam and beam types of torque tools To send the displayed torque reading to a PC via RS232 press RESET button which will...

Page 12: ... to turn unit off Select units select mode set limits reading Increase selected number Cycles back to zero Set limits Move right between different mode selections units of numbers Cycles back to first number Set limits select mode select units Move left between different mode selections units of numbers Select mode select units Cycle through RUN 1st PEAK and PEAK RUN 1st PEAK and PEAK reading Tare...

Page 13: ...calibrate the transducer to the selected torque range STORE Will store the selected torque range ORDER OF CALIBRATION 1 Fit transducer in appropriate Calibration machine 2 Attach the transducer to the PTD via cable 3 Place the PTD into Calibration Mode by Pressing and holding the furthest left and furthest right soft key buttons whilst turning the PTD on This will activate the Calibration Mode 4 A...

Page 14: ...itness Systems Ltd 1010 Professional Transducer Display Operating Manual 8 Apply the amount of torque for full scale Allow this to settle for 2 Minutes 9 Press CAL and the reading will show the applied torque 10 Turn the unit off and then on The transducer is now calibrated ...

Page 15: ...1010 Professional Transducer Display Page 15 Advanced Witness Systems Ltd 1010 Professional Transducer Display Operating Manual Page intentionally left blank ...

Page 16: ...Advanced Witness Systems Ltd Unit 8 Beaumont Business Centre Beaumont Close Banbury Oxfordshire OX16 1TN Telephone 01295 266939 Fax 01295 263503 sales awstorque co uk www awstorque co uk ...

Reviews: