XR-3600 Reader Installation Sheet
Version 1.1
Page 2 of 2
Procedure
1.
Connector
– Cut off the white 10-pin connector from the end of the reader’s cable. Discard the connector.
2.
Wire Connections
– Connect the reader’s wires to the cable(s) for power and data.
a. First, connect
black
to the panel port’s Ground terminal, and, if separate, to the power supply Negative.
b. Connect
green
to the Data-0 terminal. Connect
white
to the Data-1 terminal.
c. Connect the
gray
drain wire to the shield of the connecting cable.
If power and data are in separate cables, connect all three drain/shields together near the reader.
d. At the end of the cable(s) near the panel (and near the power supply, if separate), connect the
shield
to a
verified earth-ground.
e. Last, connect
red
to the DC Positive terminal.
3.
Reader Mounting
– Feed the reader’s cable through the cable opening in the mullion or wall. Mark and
drill lead-holes in the surface where the reader will be mounted. Fasten the reader to the mullion or wall,
with screws through the holes at the ends of the reader. Use supplied screws if suitable.
4.
Screw-Hole Plugs
–
After
you have tested the reader,
press the plugs over the screw heads in the reader.
5.
Reader Test
– When power is applied to the XR-3600, the LED initializes to steady-red for standby, and
the beeper sounds. With every presentation of an AWID UHF card to the reader, the LED changes color
momentarily, and the beeper sounds briefly. Read range with a compatible AWID card is up to 6 inches.
6.
System Test
– Wire the reader to the system’s controller. Program the code for the AWID UHF card or
keytag into the host system, with full priority, all doors groups, and all time zones. Present the card or
keytag to the reader. Observe door unlock or gate opening, indicating “Access Granted” by the system.
Technical Support
● Call 408-825-1100, option 1. E-mail
.