MR-1824HiLo/MC Installation Sheet 

Version 2.2 / Doc# 041509 

Page 2 of 3 

 

4. 

Wire Connections

  –  Connect the “HiLo” units’ wires to the cables for power, data, and controls. 

a.  Start the wiring by connecting together these corresponding wires (same insulation color) on the two reader units: 

 

3 Wiegand data lines – 

green

white

 and 

black

 

1 or 2 external control lines – 

brown

 for LED, 

yellow

 for beeper/alarm, if they are used.  (Do 

not

 use 

blue

.) 

 

2 DC power lines – 

black

 and 

red

.  (If each “HiLo” unit has its own DC power supply, omit this step.) 

 

b.  Next, connect the reader’s 

black

 wire to the panel port’s Ground or Negative or Data Common terminal, 

  

and also

 to the power supply’s Negative terminal. 

 

c.  Connect the reader’s 

green

 wire to the Data-0 terminal.  Connect the 

white

 wire to the Data-1 terminal. 

 

d.  For alternating control of the two units, connect one unit’s 

orange

 wire to the 

violet

 wire of the other unit; 

  

also, connect the first unit’s 

violet

 wire to the other unit’s 

orange

 wire. 

 

e.  Connect the 

gray

 drain wire to the shield of the connecting cable. 

  

If power and data are in separate cables, connect all three drains/shields together near the reader. 

 

f.  If the LED and/or Beeper/Alarm features are used, connect the 

brown

 and/or 

yellow

 wires. 

 

g.  At the end of the cable(s) near the panel and near the power supply, connect the cables’ 

shield

 to a 

 

verified earth-ground. 

 

h.  Last, connect 

red

 to the DC power supply’s Positive terminal. 

 

         

 