ATEX Retractor System TANKO-RT/-RTS
5 Installation
Translation - Operating/installation instructions 2020/01
65/121
8. Cleaning medium supply (standard: Clamp DN25 in accordance with DIN 32676) on the media
connection (hydraulic pipe) with suitable gasket and clamp.
Special Vessel Combination Adapter
Figure 5.2-8: Special Connection
A special vessel connector is available for different TANKO-RT installation angles from a horizontal
position to a maximum of 30°.
For welding in, the connector may not be inserted deeper than a maximum of L (52 mm) into the
container (see
The connector can be prepared for the intended angle at additional cost.
More detailed information is available from the ordering documents; if you have any questions, please
consult AWH.
5.2.3.4
Installation of the Device with Process Connection: BioControl
®
The sealing points are the crucial part of the BioControl
®
connection and have been
manufactured and packed by AWH with the utmost care and precision.
When handling the BioControl® connection, the sealing elements can very easily suffer
damage.
Protect sealing elements from damage and contamination during transportation, storage,
assembly and cleaning!
The block flange BioControl
®
B65 and the O-ring 60 x 3
for process connection, as well as
gasket and bracket (or screws for a screwed flange, special design) for media connection are
not included in the scope of delivery; please request gasket and bracket from AWH, request
block flange, O-ring and 4x screws M10x18 from NEUMO
.
1. Take the retractor system out of the packaging and perform a visual inspection for damage.
2.
NOTE
Careless installation of the O-ring can negatively affect its sealing and hygienic functionality.
Observe the installation instructions for BioControl
®
from NEUMO!
In accordance with the installation instructions from NEUMO, pull the O-ring for the block flange
forwards onto the hydraulic pipe, keeping the O-ring and O-ring groove clean.