Jet Cleaner TANKO-JM
7 Maintenance
Translation of the original Operating / Installation Instructions 2016/12
51/90
recommended minimum dimensions for the installation opening and for installing the device in the
container and removing it from the container in assembled condition.
A
“
stationary device
”
can be removed in different ways depending on the properties of the container
and the size and accessibility of the installation opening.
–
Before removal, the downpipe [DP] is disconnected from the process connection [PC] and lifted out
of the container through the installation opening from the outside, together with the device.
The device is then disconnected from the downpipe [DP] at the media connection [MC] or
–
the device is disconnected from the downpipe [DP] at the media connection [MC] inside the
container.
WARNING
Risk of the device falling accidentally!
The device may strike personnel when falling.
There is a risk of severe physical injuries.
Hold the device firmly when installing/removing it.
There must be nobody beneath the device when installing/removing it.
NOTE
No torque may be initiated into the device via the nozzles while the device is being
installed/removed! Lever action can cause a torque to be transferred via the nozzle carrier to the bevel
gear wheels.
The threaded connections of the bevel gear wheels could become loose.
When setting the device down with the downpipe fastened in place, make sure that the nozzles ARE
NOT under pressure due to the weight and length of the downpipe.
Clamp the downpipe in a vise so that the device can be fastened to the downpipe or loosened from it.
Interface A
The supply line for the cleaning agent must be disconnected at the media connection [MC] . The media
connection [MC] is to be sealed with a screw cap.
For threaded connection
(see
Figure 5.2-7: Assembly of threaded connection (example JM100)
1. Undo the connection cover threaded connection (01) / media supply pipe with an open-end wrench
or an adjustable pliers wrench.
2. Unscrew the device from the pipe for the media supply.
3. Provide the media connection [MC] with a suitable screw cap/sealing plug.
Interface B
NOTE
Excessively small installation openings on the container!
Risk of damage to the device or its surroundings.
Before undoing the process connection [PC], check whether the device can be lifted out together
with the cleaning head through the installation opening of the container (see
section 3.3
The instructions for interface
“
C
”