background image

www.awg-fire.com

43 Summer St.
South Walpole, MA 02071
Tel (508)-850-5260
Fax (508)-850-5262

3

Mar-11

Safety and Cautions 

This equipment is to be used by trained firefighting personnel only.  Failure to 
obtain proper training  may result  in severe injury or death. 

Do not exceed maximum operating pressure.  Exceeding the maximum rated 
pressure for this appliance may cause malfunction, or failure resulting in severe 
injury or death. 

Failure of fittings and hoses can result in injury.  Use caution not to exceed hose 
pressures as stated in NFPA 1961 for the type of hose being  used. 

Make sure all connections are secure and complete.  Failure to ensure proper 
connection may result in leaks or cause the devices to become disconnected 
under pressure resulting in injury or death. 

Open and close all valves slowly.  Failure to operate valves slowly may cause 
water hammer, which may result in damage or failure of hose, coupling devices, 
and appliances leading to injury or death. 

Do not use if damaged.  Damage to product may cause malfunction or failure.  
Remove from service until unit can be repaired. 

Check for damage or worn coupling connections.  Damaged or worn connections 
may become disconnected under pressure.  Remove from service to be repaired 
by an AWG certified repair facility. 

For use with fresh or salt water, with or without firefighting foam. 

Altering of this device may reduce its operating effectiveness, or safety.  Do not 
alter or change in any way from its intended design.

2.0 Safety and Cautions

Meaning of safety words

Summary of Contents for 30277633

Page 1: ...gs LLC Pressure Relief Valve Up to 200PSI Product number 30277633 Read this instruction manual before use Using this device without understanding this product s operation and care may lead to injury I...

Page 2: ...reasonable time period If AWG Fittings LLC determines that the product is defective then it will replace the product repair the product or refund the purchase price at AWG Fittings LLC s election Thi...

Page 3: ...may result in leaks or cause the devices to become disconnected under pressure resulting in injury or death Open and close all valves slowly Failure to operate valves slowly may cause water hammer wh...

Page 4: ...2 4 Mar 11 Dimensions Height 4 3 in 110 mm Length 6 29 in 160 mm Depth 4 25 in 108 mm Weight 3 5 lbs 1 6 kg Construction Aluminum body and anodized aluminum piston Operating pressures Adjustable from...

Page 5: ...our setting before placing the unit in service If the relief valve operates continually fails to operate or water leaks slowly through the relief valve during use remove from service until valve can b...

Page 6: ...screw is set flush with the top cover the highest vertical setting the relief valve is set to open at 100 PSI When the adjustment screw is set in its middle position the top of the screw will be flus...

Page 7: ...ef valve should be exercised every six months to keep the internal components clean and to make sure all parts are working properly Adjust the set screw to the lowest available setting 100 PSI Attach...

Page 8: ...hould open and discharge water from the PRV If water is not flowing from the relief valve slowly increase the pressure to 210 PSI Check for water flow from the relief valve The relief valve should ope...