REGULATORY NOTES

FCC PART 18

This device complies with part 18 of the FCC rules for non-consumer industrial, 
scientific and medical (ISM) equipment.

This instrument is enclosed in a rugged metal chassis and uses a filtered power entry 
module (where applicable). The main output signal is provided on a shielded connector 
that is intended to be used with shielded coaxial cabling and a shielded load. Under 
these conditions, the interference potential of this instrument is low.

If interference is observed, check that appropriate well-shielded cabling is used on the 
output connectors. Contact Avtech ([email protected]) for advice if you are unsure
of the most appropriate cabling. Also, check that your load is adequately shielded. It 
may be necessary to enclose the load in a metal enclosure.

If any of the connectors on the instrument are unused, they should be covered with 
shielded metal “dust caps” to reduce the interference potential.

This instrument does not normally require regular maintenance to minimize interference
potential. However, if loose hardware or connectors are noted, they should be 
tightened. Contact Avtech ([email protected]) if you require assistance.

EC DECLARATION OF CONFORMITY

We

Avtech Electrosystems Ltd.
P.O. Box 5120, LCD Merivale
Ottawa, Ontario
Canada  K2C 3H5

declare that this pulse generator meets the intent of Directive 2004/108/EG for 
Electromagnetic Compatibility. Compliance pertains to the following specifications as 
listed in the official Journal of the European Communities:

EN 50081-1 Emission

EN 50082-1 Immunity

7

Summary of Contents for AVMR-2D-B

Page 1: ...BER 13997 A V T E C H E L E C T R O S Y S T E M S L T D N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 info avtechpulse com http www avtechpulse com Tel 888 670 8729 USA C...

Page 2: ...r or replace said defective item This warranty does not apply to units which have been dissembled modified or subjected to conditions exceeding the applicable specifications or ratings This warranty i...

Page 3: ...CHECK 10 POWER RATINGS 10 CONNECTION TO THE POWER SUPPLY 10 PROTECTION FROM ELECTRIC SHOCK 11 ENVIRONMENTAL CONDITIONS 12 LABVIEW DRIVERS 12 FUSES 13 AC FUSE REPLACEMENT 13 DC FUSE REPLACEMENT 14 FUSE...

Page 4: ...NG 31 WIRING DIAGRAMS 32 WIRING OF AC POWER 32 WIRING OF DC POWER 33 PCB 158R5 LOW VOLTAGE POWER SUPPLY 34 PCB 235C HIGH VOLTAGE DC POWER SUPPLY 35 PCB 216E PRF PW TWEAKING PCB 36 PCB 231A INTERNAL DC...

Page 5: ...g at 3 4V approximately An internal relay switched 15 dB attenuator is used to provide the lower amplitudes The AVMR 2D B is a highly flexible instrument Aside from the internal trigger source it can...

Page 6: ...SMA one BNC for use on external trigger inputs Optional accessory kit coaxial cables and adapters Add the suffix AK8 to the model number to include the recommended accessory kit Consists of one 12 inc...

Page 7: ...g Also check that your load is adequately shielded It may be necessary to enclose the load in a metal enclosure If any of the connectors on the instrument are unused they should be covered with shield...

Page 8: ...tion of conformity is issued under the sole responsibility of Avtech Electrosystems Ltd Specifically products manufactured do not contain the substances listed in the table below in concentrations gre...

Page 9: ...9 have been made Requirements for WEEE compliance may include registration of products with local governments reporting of recycling activities to local governments and financing of recycling activiti...

Page 10: ...mal single phase supply CONNECTION TO THE POWER SUPPLY An IEC 320 three pronged recessed male socket is provided on the back panel for AC power connection to the instrument One end of the detachable p...

Page 11: ...erators are prevented access and or are insulated from every connection point In some cases connections must be exposed to potential human contact Operators must be trained to protect themselves from...

Page 12: ...C decreasing linearly to 50 relative humidity at 40 C 5 Mains supply voltage fluctuations up to 10 of the nominal voltage 6 no pollution or only dry non conductive pollution LABVIEW DRIVERS A LabVIEW...

Page 13: ...the fuses on the rear panel are shown in the figure below AC FUSE REPLACEMENT To physically access the AC fuses the power cord must be detached from the rear panel of the instrument The fuse drawer ma...

Page 14: ...Nominal Mains Voltage Rating Case Size Recommended Replacement Part Littelfuse Part Number Digi Key Stock Number 1 2 AC 100 240V 0 5A 250V Time Delay 5 20 mm 0218 500HXP F2416 ND 3 DC N A 1 6A 250V Ti...

Page 15: ...bout 5 seconds after which the instrument will attempt to re enable the output i e light green for about 1 second If the overload condition persists the output will be disabled again i e light yellow...

Page 16: ...numeric parameters is displayed this decreases the setting by a factor of ten If one of the adjustable numeric parameters is displayed and this parameter can be both positive or negative this changes...

Page 17: ...e instrument This input can be either active high or active low depending on the front panel settings or programming commands The instrument triggers normally when this input is unconnected When set t...

Page 18: ...This Ethernet connector allows the instrument to be remotely controlled using the VXI 11 3 ssh secure shell telnet and http web protocols See the Programming Manual for B Instruments for more details...

Page 19: ...elay is set to a positive value the SYNC pulse precedes the OUT pulse When the delay is set to a negative value the SYNC pulse follows the OUT pulse These pulses are illustrated below assuming interna...

Page 20: ...ment controls the trigger frequency and generates the clock internally External Trigger the instrument is triggered by an external TTL level clock on the back panel TRIG connector Manual Trigger the i...

Page 21: ...ggering Pulses are not truncated OPERATION AT LOW AMPLITUDES This instrument will generate the best waveforms when operated near maximum amplitude If amplitudes less than 4 of the full scale value are...

Page 22: ...s option adds a bias tee circuit on the output and adds an internal 0 to 5V DC bias source The offset level can be set by the front panel controls or by computer commands The internal DC source is act...

Page 23: ...strument should be turned off when the instrument is not in use In the case of failure the switching elements are easily replaced following the procedure described in a following section DO NOT EXCEED...

Page 24: ...the sampling scope vertical input channel will insure a peak input signal to the sampling scope of less than 1 Volt Factory tests are conducted using Mini Circuits model BW S20W2 attenuators b The TRI...

Page 25: ...menu item b Press the CHANGE button The delay submenu will appear Rotate the ADJUST knob until the delay is set at 100 ns c The arrow pointer should be pointing at the Normal choice If it is not pres...

Page 26: ...ing scope controls d Rotate the ADJUST knob The amplitude as seen on the oscilloscope should vary Return it to 10V e PN units only Press the button on the front panel The amplitude as seen on the osci...

Page 27: ...n turns on the output For triggering a single event this sequence would be more appropriate rst resets the instrument trigger source hold turns off all triggering pulse width 50 ns sets the pulse widt...

Page 28: ...e PERiod numeric value WIDTh numeric value DCYCle numeric value HOLD WIDTh DCYCle DELay numeric value GATE TYPE ASYNC SYNC LEVel HIgh LOw SOURce VOLTage LEVel IMMediate AMPLitude numeric value EXTerna...

Page 29: ...er SOURce INTernal EXTernal MANual HOLD IMMediate CLS no query form ESE numeric value ESR query only IDN query only OPC SAV 0 1 2 3 no query form RCL 0 1 2 3 no query form RST no query form SRE numeri...

Page 30: ...factory for repair Service is to be performed solely by qualified service personnel Caution High voltages are present inside the instrument during normal operation Do not operate the instrument with t...

Page 31: ...es may require replacement All fuses can be accessed from the rear panel See the FUSES section for details CLEANING If desired the interior of the instrument may be cleaned using compressed air to dis...

Page 32: ...st G 1 G 2 B1 G 4 G 3 L N G X2 CORCO M6EGG 1 2POWERENTRY M O DULE 1 1b 1a 2 2b 2a X1 POWERSWITCHSW325 ND CWINDUSTRIES G RS 4022 0013 A1 BRO WN A2 BLUE A3 BLACK A4 WHITE GR N AMB D1 P395 NDLED GRN AMB...

Page 33: ...9 FAN J10 GND GND GND 20 AWG C J12 GND C J8 GND J11 X1 PCB158R5 CHSGND 15 O Y 10KOY NOTUSED 4 7K 5K 3266W NOTUSED 0 TO 36V VAR APDGND HV HV HV HV GND LV SSR N C VC 235B R3 R5 R6 R7 R8 R9 U1 R10 R11 PS...

Page 34: ...PCB 158R5 LOW VOLTAGE POWER SUPPLY...

Page 35: ...PCB 235C HIGH VOLTAGE DC POWER SUPPLY...

Page 36: ...PCB 216E PRF PW TWEAKING PCB...

Page 37: ...PCB 231A INTERNAL DC OFFSET FUNCTION...

Page 38: ...PCB 151D RANGE POLARITY RELAY BOARD...

Page 39: ...2015 ddb Documents Panelbrd prj PANELTOP LEVELSCHEMATIC 1 2 3 4 5 6 7 8 9 10 J5 Amp 54999 10 1 10 pin straight head er I2C_INT SC L SDA GND VC C SINGLE PULSE BACKLIGHT ENCODER ENCODER S CH I2C_INT SC...

Page 40: ...UST HAVE A IN P N VC C 1A 1B X2 82 101 71 1 b utton keypad 1 2 U4 A MM74HC 14N 11 10 U1 E MM74HC 14N SINGLE PULSE VC C VC C C1 0 2 2uF C1 1 2 2uF C1 2 2 2uF C9 2 2uF C7 2 2uF C6 2 2uF C1 2 2uF 3 4 U4...

Page 41: ...DA SC L VC C VC C GND VC C VC C C5 0 1uF 1 2 U1 A MM74HC 14N 13 12 U1 F MM74HC 14N 5 6 U1 C MM74HC 14N PAD3 LED PAD4 LED X3 4 40 MOUNT X1 4 40 MOUNT X9 4 40 MOUNT X8 4 40 MOUNT 3 4 U1 B MM74HC 14N LC...

Page 42: ...15V 4 15V 5 BD4 PCB231A OT N O COM N C K2 401 2308 24V N O COM N C K1 401 2308 24V M4 BW S15W2 CONN2 GATE CONN3 EXTTRIG 15V CHSGND 15V 24V NO OLO C HA NG ES R EQ UIR EDO NPCB151D 1 R EM O VER12 ON E...

Page 43: ...PERFORMANCE CHECKSHEET...

Reviews: