SPECIFICATIONS
Model:
AVIR-2-B
2
Amplitude
3,4,5,9
:
< 20 to 200 Volts (50Ω load required)
Pulse width (FWHM)
4
:
3 - 10 ns
Rise time (20%-80%):
≤ 1.5 ns
Fall time (80%-20%):
≤ 2 ns
PRF:
0 to 20 kHz
Polarity
6
:
Positive or negative or both (specify)
GPIB & RS-232 control
2
:
Standard on -B units.
LabView Drivers:
http://www.avtechpulse.com/labview
for availability and downloads
Ethernet port, for remote
control using VXI-11.3,
ssh, telnet, & web:
Optional
7
. Recommended as a modern alternative to GPIB / RS-232.
http://www.avtechpulse.com/options/vxi
Settings resolution:
The resolution varies, but is always better than 0.15% of the set value.
Settings accuracy:
Typically ± 5% (plus ±2 V or ± 2 ns) after 10 minute warmup.
For pulse widths below ~10 ns, the amplitude accuracy degrades to ± 10% ± 10 V.
For high-accuracy applications requiring traceable calibration,
verify the output parameters with a calibrated oscilloscope.
Propagation delay:
≤ 100 ns (Ext trig in to pulse out)
Jitter:
± 35ps ± 0.015% of sync delay (Ext trig in to pulse out)
DC offset or
bias insertion:
Optional
8
. Apply required DC offset or bias in the range of
± 50 Volts (250 mA max) to back panel solder terminal..
Trigger required:
Ext trig mode: + 5 Volts, 50 ns or wider (TTL)
Sync delay:
Sync out to pulse out, variable 0 to ± 500 ns
Sync output
+3 Volts, 100 ns, will drive 50 Ohm loads
Connectors:
Out: SMA, Trig/Sync, Gate (-B only): BNC
Power requirement:
100 - 240 Volts, 50 - 60 Hz
Dimensions:
H x W x D: 100 × 430 × 375 mm (3.9 × 17 × 14.8”)
Chassis material:
Aluminum
Rack-mount kit:
Optional. To specify, add the -R5 suffix to the model number.
Temperature range:
+5°C to +40°C
1) -C suffix indicates stand-alone lab instrument with internal clock and line powering.
2)
-B suffix indicates IEEE-488.2 GPIB and RS-232 control of amplitude, pulse width, PRF and delay (see
http://www.avtechpulse.com/gpib
3) For electronic control (0 to +10V) of amplitude, suffix the model number with -EA. Includes standard front-panel controls. Not available on AVIR-4
models.
4) For 10-turn dial control of pulse width (or amplitude) suffix model number with -PWT (or -AT). Not applicable for -B units.
5) For operation at amplitudes of less than 10% of full-scale, best results will be obtained by setting the amplitude near full-scale and using external
attenuators on the output.
6) Indicate desired polarity by suffixing model number with -P or -N (i.e. positive or negative) or -PN for dual polarity option. Polarity reversal is achieved
by means of a two-position switch.
7) Add the suffix -VXI to the model number to specify the Ethernet port.
8) For DC offset option suffix model number with -OS.