Avsl primalux 522.010UK User Manual Download Page 2

 

 

522.010UK User Manual 

 

Testing 

 

 

After installation, turn the LUX switch clockwise to the maximum setting 

(SUN)

 

 

Turn the TIME switch anti-clockwise to the minimum setting (-)

 

 

For extra guidance please see picture.

 

 

Turn on the power to test, if no light output 
check settings after 30 seconds. 

 

 
 

Note: 

When testing the sensor in daylight, please turn the ‘Lux’ switch to

    

(SUN) position, otherwise the sensor lamp could not work. 

 

Specification  
 
Power Source

 

……………………………………………….

220-240Vac (50/60Hz) 

Ambient Light 

…………………………………………… 3

-2000 Lux (adjustable) 

Time Delay Minimum 

……………………………. 

10 Seconds ± 3 Seconds 

Time Delay Maximum 

……………………………..… 5 Minutes 

± 1 Minute 

Rated Load 

…………………………………………………………………………. <60W 

 

Detection Distance 

…………………………………..……… 

6m MAX (<24°C) 

Detection Range 

…………………………………………………………………. 360°

 

IP Rating 

…………………………………………………………………………….... IP20

 

Installation Height 

……………………………………………………… 2m

-3.5m 

 

 

 

Errors and omissions excepted. 

 

Copyright© 2019. AVSL Group Ltd. 