background image

GSM engine connection

S1

F1 F3.15A L250V

C

O

N

N

G

S

M

PROG.

BATT.

SW1

T

TAMPER

TAMPER

S2

F2 F3.15A L250V

RV5

GSM

T

PB1

RESET

PB2

CENTR.

Bc

3

OUT STATE

O

FF

 T

T

2

1

S3

Ac

A B

Bc

CENTR.

Ac

A

RV4

RV2 RV3

RV1

V

E

C

T

O

R

 M

A

0

0

3

3

3

V

3

/2

B

Modulo

GSM

Connect the GSM engine to 30 pin female connector.

Plugging in sim card / antenna jack

GSM engine with upper side SIM Card holder:

1. Press pushbutton

 A

.

2. Extract 

B

 holder.

3. Put SIM card on 

B

.

4. Insert 

B

 holder all the way long into its receptacle.

GSM engine with right side SIM Card holder:
To insert SIM Card:

1. Insert SIM Card completely into slot

  C

 until it clicks inside

the module

To remove SIM Card:

1. Press and release the SIM Card to cause it to be ejected
through the slot.

Antenna jack:

Place the male connector of the antenna
cable into the female one of the module
and apply slight pressure in the axis
direction to click it into the module. 

Do not

force or bend the cable sideway. 

To

remove the cable, hold the connector with
the fingertips and pull avoiding bending it
sideway. 

Do not pull the cable.

Display module connection

Remove power from the interface and
insert the display module into the proper
connectors as indicated in the figure.

7

GSM engine

A

B

C

Ingresso connettore antenna

Input antenna jack

Summary of Contents for VECTOR Plus

Page 1: ...Curtarolo Padova Italy www avselectronics com VECTOR Plus Bidirectional INTERFACE INSTALLATION MANUAL IST0401V2 1 QUALITY SYSTEM ISO9001 ...

Page 2: ...s 8 sms functions 7 display module connection 7 plugging in sim card antenna jack 7 gsm engine connection 6 settings 6 input and output 6 leds 6 dip switches 5 jumpers and trimmers 5 testing vector plus 5 other display indications 4 display module 4 installation 4 important warnings 3 gsm compatibilities see technical updates sheet 3 technical characteristics 3 operation 3 features 2 ...

Page 3: ...lus generates the dial tone signal like the normal telephone line and waits the dialling sequence from the external device only DTMF dialling is accepted After the dialling sequence is completed the call is routed through the GSM unit and VECTOR Plus generates the ringing tone and or busy tone Once the GSM connection is established the voice channel stays open allowing data and voice signals trans...

Page 4: ......

Page 5: ... level 5 Battery problem only when using standard cell phone 6 Unknown general problem Testing VECTOR Plus In order to verify the efficiency and the signal quality of the GSM channel we suggest the following test connect a normal telephone set to terminals Ac Bc of the interface and close to negative the terminal GSM Power up the unit and wait the initialization process is completed see display Ex...

Page 6: ...F DIP 1 OFF LEDs LD1 shows the GSM module operation status flashing GSM module is registered in the network and in stand by on a GSM call is taking place off the GSM module is NOT correctly registered in the network failure condition LD2 must be always ON indicating that the GSM module is working NOTE this two leds will activate only when using the industrial GSM module Input and output GSM input ...

Page 7: ...nsert SIM Card 1 Insert SIM Card completely into slot C until it clicks inside the module To remove SIM Card 1 Press and release the SIM Card to cause it to be ejected through the slot Antenna jack Place the male connector of the antenna cable into the female one of the module and apply slight pressure in the axis direction to click it into the module Do not force or bend the cable sideway To remo...

Page 8: ...numbers because it is the one which technical SMS messages are sent to by default otherwise differently specified in configuration parameter 1 Apart from the technical SMS that are automaticly sent by VECTOR Plus once they has been enabled through the configuration numbers the remaining SMS stored into the SIM card by the installer to communicate any kind of alarm or status information can be sent...

Page 9: ...d up with a different text to be sent by command when needed TT is the position into the SIM card phonebook of the telephone number to which the SMS message has to be sent Like for the text messages the position of telephone numbers also depends on the order they were stored into the SIM card when programmed Issuing 99 as the value of TT the selected SMS message will be sent to all telephone numbe...

Page 10: ...the interface while the telephone number is being dialled NOTE 1 using AVS ELECTRONICS diallers or control panels setting to 0 the number of attempts of telephone calls will cause the dialler to make one single calling attempt NOTE 2 if the telephone number for SMS activation is not the first number called by the dialler once the GSM input terminal of VECTOR Plus has received the pulse to negative...

Page 11: ...6 5 4 3 2 1 Telephone number Name saved Posit on M add 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 Telephone number Name saved Posit on M add 14 13 12 11 10 9 8 7 6 5 4 3 tecn 2 tecn 1 tecn SMS Description N SMS 28 27 26 25 24 23 22 21 20 19 18 17 16 15 SMS Description N SMS ...

Page 12: ...ugana 63 35010 Padova ITALY Tel 049 96 98 411 Fax 049 96 98 407 avs avselectronics com www avselectronics com AVS ELECTRONICS S p A reserves the right to modify the technical and esthetical characteristic of the products at any time ...

Reviews: