- 31 -
IST1054V1.0
Fuses
F1 - T 500mA 250V
Protection of the transformer primary
F3 - F 6,3A 250V
Fuse protecting 220 V network input
Buttons
RESET
Press and release to reset the microprocessor
Dip Switch
DIP SWITCH
DESCRIPTION
DEFAULT
1
OFF
Activates the delivery warning buzzer - notice time 1 ‘
OFF
ON
Disable the delivery warning buzzer - notice time 1 ‘
2
Not used
- DO NOT CHANGE FROM THE DEFAULT POSITION
OFF
3
OFF
Normal operation
OFF
ON
Reset Eeprom.
See related description.
4 - 5 - 6 - 7
Not used -
DO NOT CHANGE FROM THE DEFAULT POSITION
OFF
8
OFF
Normal operation
OFF
ON
Firmware update. See related description.
9
Not used -
DO NOT CHANGE FROM THE DEFAULT POSITION
OFF
10
OFF
Buzzer disabled
OFF
ON
Buzzer enabled
Signals
LED
RED
-
-
DISARMED:
System not armed
ARMED:
System armed
GREEN
-
-
-
DISARMED:
cold liquid - impossible to supply in case of alarm
FLASHING:
low liquid temperature - with this signal, dispensation is possible only if it has
already
started with the liquid in appropriate temperature
ARMED:
SANY SAFE is operating regularly and the boiler is at operating temperature
The led indicates the temperature and not the boiler heating activity, signaled instead on
the display with the letter H
YELLOW
-
-
-
DISARMED:
no anomaly
FLASHING:
non serious anomalies (see System anomalies chart)
ARMED:
signal for serious anomalies or TAMPER (see System anomalies chart)
In case of more simultaneous signals, the yellow led indicates the most important
LED DISPLAY
-
Separator:
if there are multiple simultaneous signals, this symbol is placed between messages
BOILER STATUS
H
Heating: Boiler heating in progress
r
Ready: System ready to start smoke deplyment
ERROR SIGNAL
Led yellow
E1
On steady
Error in temperature control calibration.
In the presence of this signal, boiler heating will be blocked.
E3
On steady
PUMP Malfunctioning
E4
On steady
PCB temperature not correct
E5
On steady
GSM module fault
E6
On steady
Excessive BOILER temperature
E7
On steady
Boiler temperature too low.
This indication is signaled at the fi rst power supply or after a
dispensation if the temperature does not return to normal within a certain pre-established
time or during normal function when the boiler temperature drops below the minimum working
temperature threshold.
In presence of this signal, dispensation will not occur.
E8
Flashing
Liquid low or exhausted