RS485 network connection diagram
The setup for RS485 is a parallel network. To connect multiple cameras by RS485, the cameras
need to get attached to a 2-wire twisted pair bus that is terminated at both ends with a 120
Ω
impedance resistor. The maximum length of the bus is 1200m. The maximum distance from the
bus to the camera or controller is 5 meters. The cameras are connected with the 2-pin Phoenix
connector. In the OSD menu under Communication Setup, Net mode is set to Paral.