Chapter 2: Installation
19
Making Cascade Connections
The Emerge EMS series of products have been specifically designed to be flexible in order to
support both your immediate and future needs for media streaming. In addition to the standard
connections made from transmitters to receivers, you can also link extra transmitters to
transmitters in order to provide more display/speaker outputs. These non-standard links are called
cascade connections
.
Important Limitations When Cascading Emerge EMS units
•
There should never be more than
three
cascade connections between the
Primary Transmitter
(the one connected to the source PC) and any receiver. Cascade connections are possible only
at the transmitter end of the link cable(s).
•
It is essential that the source PC, all EMS2400T modules and all connected displays are
configured to use the same serial communication settings (see
Switch setting
s
for details). The
EMS2100T, EMS2100R & EMS2110R modules all auto-sense the serial configuration and do
not need to be set.
•
Each cascade connection reduces the overall link length permissible from a transmitter to the
final receiver in a branch. To calculate the recommended overall maximum link length for a
branch, count the number of cascade connections between the
Primary Transmitter
and the
final receiver in that branch. The effects of cascade connections on overall branch link lengths
are as follows:
Table 2.1: How cascade connections affect overall maximum link cable lengths (EMS2400T)
Number of cascade connections
Overall length of links for the branch
(in a branch)
(from transmitter to furthest receiver)
0
1000 feet (300m)
1
800 feet (250m)
2
650 feet (200m)
3
600 feet (175m)
Notes
EMS2100R models should always be limited to link lengths of 600 feet or less, regardless of
cascade connections, due to a lack of skew compensation adjustments.
The lengths of transmitter cascade connections should never be longer than 6 feet and can be
considered to have a negligible effect upon overall link lengths.
The maximum resolutions achievable are: 1600 x 1200 x 60 Hz at 200m and 1280 x 1024 x 60Hz
at 300m. If you are using lower resolutions then it may be possible to achieve longer transmission
distances than shown in the above table although we do not recommend runs longer than 1000ft
in any installation. If you are running shorter cables then it may be possible to use more cascades
than shown in the above table.
Summary of Contents for Emerge EMS2000 series
Page 1: ...Emerge EMS2000 series Installer User Guide ...
Page 6: ...iv Emerge EMS 2000 series Installer User Guide ...
Page 8: ...vi Emerge EMS 2000 series Installer User Guide ...
Page 42: ...34 Emerge EMS 2000 series Installer User Guide ...
Page 47: ...39 ...
Page 48: ...For Technical Support www avocent com support 092108 00UG ...