21
Cascading Receivers (Emerge EMS1000MP-R Receivers Only)
Expansion at the receiver end is made possible using the
LINK OUT
ports
present on Emerge EMS1000MP-R receivers. Receiver cascade links are
made using twisted pair cables, specified to Category 5 or higher.
Video Image Adjustments
As link cable lengths increase and more receivers are cascaded, color separation effects may
become noticeable within displayed video images, particularly at higher resolutions. These effects
are called ‘skew’ and result from differing delays on the red, green and blue color signals as they
travel to the receivers. Each Emerge EMS1000MP-R receiver provides two extra adjustment dials
to counter skew effects. For further information, please refer to the section
Skew Compensation
Adjustments
within Chapter 3.
CASCADE LINK
CASCADE LINK
EMS
1000MP
(R)
EMS
1000MP
(R)
EMS
1000MP
(R)
POWER
Figure 2.19: Connecting multiple receivers in a cascade arrangement
NOTE:
Ensure that there
are no more than three
cascades (transmitter or
receiver cascades) between
the primary transmitter and
the furthest receiver in any