background image

10

        E

merge

 1000 Installer/User Guide

Figure 3.2: Local System Information

Figure 3.3: Remote System Information

Summary of Contents for Emerge 1000

Page 1: ...Installer User Guide Emerge 1000 ...

Page 2: ...NGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons PROTECTIVE GROUNDING TERMINAL This symbol indicates a terminal which must be connected to earth ground prior to making any other connections to the equipment ...

Page 3: ...Avocent logo The Power of Being There and Emerge are trademarks or registered trademarks of Avocent Corporation or its affiliates All other marks are the property of their respective owners 2005 Avocent Corporation All rights reserved 590 549 501A ...

Page 4: ...ns Operation of this equipment is a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense Canadian Notification This digital apparatus does not exceed Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications ...

Page 5: ...r 7 Configuring keyboard layout and emulation for the receiver via the OSD 8 Configuring keyboard layout and emulation for the transmitter via the OSD 8 Configuring your OSD hotkey sequence 9 Activating OSD Timeout 9 Displaying system information 9 Upgrading Your ECMS1000R Receiver and Transmitter via Bootloader 11 Activating bootloader 12 Bootloader features 13 Appendices 19 Appendix A Technical ...

Page 6: ...iv Emerge 1000 Installer User Guide ...

Page 7: ...e with virtually any PC display technology and operating system Installation requires no new drivers or software Figure 1 1 ECMS1000R Receiver Compatibility with Peripherals The Emerge 1000 extender is compatible with the following peripherals Keyboard The Emerge transmitter and receiver support standard PS 2 and USB keyboards Mouse The Emerge transmitter and receiver support 2 button PS 2 and USB...

Page 8: ...d monitor are on the same phase For best results they should be on the same circuit To avoid potentially fatal shock hazard and possible damage to equipment please observe the following precautions Do not use a 2 wire extension cord in any product configuration Test AC outlets at the server and monitor for proper polarity and grounding Use only with grounded outlets at both the server and monitor ...

Page 9: ...eceiver features the following mounting options allowing you to easily adapt to most work environments Under desk mounting via the horizontal mounting bracket Monitor mounting via the mounting plate accessory Rack mounting via the rack mount kit NOTE Mounting accessories are ordered separately Contact Avocent for more information Connecting the local keyboard monitor and mouse The following instru...

Page 10: ...on the back of the ECMS1000R receiver 3 Insert one end of a UTP cable into the LINK port on the rear of the ECMS1000R receiver 4 Route the UTP cable to the AMIQDM module at the remote server up to 1000 feet 300 meters away and connect them together Figure 2 1 ECMS1000R Receiver and AMIQDM Module Installation AMIQDM Module Serial Port ECMS1000R Receiver Local Peripherals USB Port External Power Sup...

Page 11: ...le keyboard monitor and mouse connectors to the appropriate ports on the back of the server 3 Connect the AMIQDM module serial and audio connectors into the appropriately labeled ports on the back of the server if desired 4 Power up the server Figure 2 2 PS 2 AMIQDM Module Keyboard Mouse Serial Video Mic Audio ...

Page 12: ...ocated on the rear of the ECMS1000R receiver NOTE Use only an Avocent supplied power supply To connect power to the ECMS1000R receiver 1 Plug the external power supply s 4 pin miniDIN connector into the DC port on the ECMS1000R receiver 2 Connect the detachable IEC power cord into the power supply 3 Plug the IEC power cord into an appropriate wall outlet ...

Page 13: ...ur extender system Internal settings such as keyboard layout emulation and hotkey sequences can be configured via the On Screen Display OSD while Flash upgrades are available via the bootloader function The OSD also displays your system settings and information about your connected transmitter NOTE Table 3 1 lists available hotkey options to access the OSD Figure 3 1 Configuration Screen ...

Page 14: ...on Duet and Pinnacle FAK keyboard emulation 5 Click Apply to save settings or click Close to exit without saving changes Configuring keyboard layout and emulation for the transmitter via the OSD To change your keyboard layout and or emulation 1 Activate the OSD by pressing the hotkey sequence Ensure the Config tab is selected 2 Click the Remote radio button to change settings for the remote transm...

Page 15: ...er can be configured to log out users after 15 minutes of inactivity To activate OSD Timeout 1 Activate the OSD by pressing the hotkey sequence Ensure the Config tab is selected 2 Click the OSD Timeout checkbox at the bottom left corner of the screen Displaying system information To display system information 1 Activate the OSD by pressing the hotkey sequence 2 Click on the Info tab 3 Click the Lo...

Page 16: ...10 Emerge 1000 Installer User Guide Figure 3 2 Local System Information Figure 3 3 Remote System Information ...

Page 17: ...l terminal commands are accessed through a terminal or PC running HyperTerminal emulation software or equivalent To access the Terminal Applications menu Connect a terminal or PC running terminal emulation software to the serial port on the back panel of the ECMS1000R receiver using a null modem cable The terminal should be set to 57600 baud 8 data bits no parity 1 stop bit and no flow control ...

Page 18: ...er 1 Activate the OSD by pressing the hotkey sequence Ensure the Config tab is selected 2 Click the Invoke checkbox in the bottom right corner of the screen 3 Click the Call button The screen closes and the ECMS1000R receiver bootloader OSD is displayed The terminal menu is now available on the serial port ...

Page 19: ...ice Figure 3 7 Active Bootloader Menu Bootloader features You can select several bootloader options using the terminal menu keyboard Resetting the ECMS1000R receiver from the terminal menu Once bootloader is active you can exit the menu and reset the device by typing 0 ...

Page 20: ...has received the first six XMODEM blocks If a wrong file is sent the update is cancelled During the transfer the terminal will provide a progress display After the transfer the flashed data is checked and the device reboots The ECMS1000R receiver may need both application and boot code updated The update release notes will specify whether one or both files are needed Always update the boot code fo...

Page 21: ...e updated separately using the XMODEM The percentage complete shows the amount for the file being transferred Transmitter boot and application upgrade via XMODEM Option 2 allows you to program the boot and application of the connected transmitter The update file has to be sent via XMODEM from the terminal software after this option is chosen Figure 3 10 Upgrade Transmitter Boot or Application Code...

Page 22: ... files are needed Always update the boot code before the application The percentage bar displays the percentage complete for a particular file Figure 3 11 Updating a Local Transmitter Transmitter FPGA upgrade via XMODEM Option 3 allows you to program the FPGA code of the connected transmitter The update file has to be sent via XMODEM from the terminal software after this option is chosen See Figur...

Page 23: ...Chapter 3 Operations 17 Displaying information about connected devices Type to display the System Information of the connected transmitter Figure 3 13 Transmitter Information Screen ...

Page 24: ...18 Emerge 1000 Installer User Guide ...

Page 25: ...10 x 188 mm 1 06 x 8 27 x 7 40 in Weight 1Kg 2 20 lb without packaging cables power supply and literature Heat Dissipation 90 K Power Consumption 25 W AC input power 25 W maximum AC input current rating A AC frequency 50 60 Hz Temperature 0 to 40 Celsius 32 to 104 Farenheit operating 20 to 50 Celsius 4 to 122 Farenheit nonoperating Humidity 0 to 95 noncondensing operating Supported Hardware Periph...

Page 26: ...sync on green as used on SGI and HP9000 composite Safety and EMC Standards EN55022 Class A EN55024 EN 61000 3 2 EN 61000 3 3 EN60950 FCC 47CFR Part15 Class A CSA C22 2 No 60950 IEC 60950 FCC 15 Class A UL 60950 third edition VCCI Class A Table A 1 Emerge 1000 Extender Product Specifications Continued ...

Page 27: ...n issue should develop follow the steps below for the fastest possible service To resolve an issue 1 Check the pertinent section of this manual to see if the issue can be resolved by following the procedures outlined 2 Check our web site at www av avocent com to search the knowledge base or use the on line service request 3 Call the Avocent Technical Support location nearest you ...

Page 28: ...rating active video If this is functioning check that the display settings for your server are set no higher than a resolution of 1024 x 768 at 60 Hz refresh rate If the monitor does not function correctly replace it As a last check plug the video cable from the monitor directly into the server to verify that the monitor is working and that the server is generating active video If this is function...

Page 29: ...est the speakers by connecting them directly to the server If they do not function correctly replace them Ensure speakers are powered Poor video quality on monitor attached to ECMS1000R receiver Ensure that the video cable from the monitor is securely plugged in to the correct connector on the ECMS1000R receiver Ensure that the video cable from the AMIQDM module is securely plugged in to the corre...

Page 30: ...24 Emerge 1000 Installer User Guide ...

Page 31: ......

Page 32: ...eland Tel 353 61 715 292 Fax 353 61 471 871 Avocent Asia Pacific Singapore Branch Office 100 Tras Street 15 01 Amara Corporate Tower Singapore 079027 Tel 656 227 3773 Fax 656 223 9155 Avocent Germany Gottlieb Daimler Straße 2 4 D 33803 Steinhagen Germany Tel 49 5204 9134 0 Fax 49 5204 9134 99 Avocent Canada 20 Mural Street Unit 5 Richmond Hill Ontario L4B 1K3 Canada Tel 1 877 992 9239 Fax 1 877 52...

Reviews: