Avlite AV-OL-IMB Installation & Service Manual Download Page 18

Latest products and information available at www.avlite.com

18

ICAO Medium Intensity Type B or Type C Obstruction Light

Universal AC & Universal DC Models

Optional GSM Monitoring & Control

The Avlite obstruction light is available with GSM Cell-Phone Monitoring, enabling operators to 

remotely monitor the status of their installation. The system can also be configured to send out SMS 

text messages or e-mail alerts to designated operators should alarm conditions be triggered, such as 

low voltage or light failure. 
Please contact Avlite Systems for operational information for GSM Monitoring & Control.

Summary of Contents for AV-OL-IMB

Page 1: ...Version 2 1 AV OL IMB AV OL IMC ICAO Medium Intensity Type B or C Obstruction Light Universal DC Universal AC Models Installation Service Manual...

Page 2: ...Version No Description Date Approved 1 0 Manual launch August 2014 S Turner 1 1 Update February 2014 W Evans 2 0 Type C added November 2015 W Evans 2 1 Flash Codes updated January 2020 W Evans...

Page 3: ...Setup Page 12 Intensity Setting Page 12 Alarm Relay Output Page 12 Optional IR Remote Control Page 13 Avlite IR Controller Universal Remote Compatibility Page 13 IR Controller Functions Page 14 Test...

Page 4: ...anitarian aid operations in the most remote toughest environments Electronics Avlite employs leading in house electronic engineers in the design and development of software and related circuitry All i...

Page 5: ...metres above ground such as telecommunication towers wind turbines buildings and other tall structures Avlite s LED obstruction lights offer an ultra bright energy efficient and cost effective lightin...

Page 6: ...6 ICAO Medium Intensity Type B or Type C Obstruction Light Universal AC Universal DC Models Impact modified UV stabilised acrylic lens Automatic night operation 200mm bolt pattern for ease of installa...

Page 7: ...erature Range 40 to 80 C 40 to 80 C Physical Characteristics Body Material 7 stage powder coated aluminium 7 stage powder coated aluminium Lens Material Impact modified UV stabilized acrylic Impact mo...

Page 8: ...ttings and electrical work should only be done by a licensed electrician Operate the light only within the indicated electrical ratings and product usage instructions To ensure that the light and peri...

Page 9: ...Ensure the tower or mast is grounded NO RF HAZARD Check the mast lighting circuit is not faulty Ensure power lines are not live NO ELECTRICAL HAZARD Avoid touching live circuits Avoid touching any co...

Page 10: ...odels AC WIRING CONFIGURATION External Internal Australia Europe UK USA Canada Active Live Brown Black Neutral Blue White Earth Green Yellow Green AC Wiring Con guration Australia Europe UK USA Canada...

Page 11: ...www avlite com 11 ICAO Medium Intensity Type B or Type C Obstruction Light Universal AC Universal DC Models Positive Brown Negative Blue DC Wiring Con guration Positive Brown Negative Blue Cable 2 co...

Page 12: ...pre set in the factory and does not need to be set by the user ALARM RELAY OUTPUT In normal operation the relay is energised Terminal contacts COMM and NC of the relay are electrically closed Termina...

Page 13: ...light will flash once The user should wait until the light responds to each keypress before pressing another key If there is no response to the keypress after 3 seconds it has not been detected by th...

Page 14: ...the configuration keys shall cause the light to flash the configured value Example Key Sequences The light flashes the current battery status The light flashes the sunset level in Lux followed by a 2...

Page 15: ...se modes can be selected either via the IR remote control or via the GSM module if fitted In Always On mode the daylight sensor is disabled and the lantern will remain ON In Standby mode the lantern i...

Page 16: ...dings are darker L I B 5 6 8 9 0 Level Sunset Dusk Sunrise Dawn 1 64 100 2 100 150 3 150 240 4 240 370 5 370 600 Default Factory Preset Error Acknowledge Indication If the key sequence is invalid or a...

Page 17: ...f earth stations using atomic clocks as the time base Continuous self checking ensures that the light will continue to run in synchronisation LIGHT ACTIVATION At power up the microprocessor checks tha...

Page 18: ...bstruction light is available with GSM Cell Phone Monitoring enabling operators to remotely monitor the status of their installation The system can also be configured to send out SMS text messages or...

Page 19: ...gh the following maintenance and servicing information is provided to help ensure the life of your Avlite product Occasional cleaning of the dome lens may be required using a cloth and warm soapy wate...

Page 20: ...OFF Battery voltage is less than 10 0V Slow High Voltage Battery voltage is above 13 5V Off Optimal Voltage Battery Voltage is between 12 5V 13 5V 1 Quick OK Voltage Battery Voltage is between 12 0V 1...

Page 21: ...m 21 ICAO Medium Intensity Type B or Type C Obstruction Light Universal AC Universal DC Models Certification Compliant to ICAO Annex 14 Volume 1 Aerodrome Design and Operations Sixth edition July 2013...

Page 22: ...three 3 years from the date of purchase by the original purchaser 4 Avlite Systems will repair or replace at Avlite s sole discretion any Telemetry Products Roto Moulded Products Accessory Products or...

Page 23: ...lity To the extent permitted by acts and regulations applicable in the country of manufacture the liability of Avlite Systems under this Warranty will be at the option of Avlite Systems limited to eit...

Page 24: ...d perimeter lighting Helipad lighting Obstruction lighting For a complete list of product compliances including ICAO FAA please contact Avlite today Helipad Lighting Airfield Markers Accessories A sub...