Latest products and information available at www.avlite.com
16
AV-OL-70 & AV-OL-70-HI
Solar Obstruction Light
Trouble Shooting
Problem
Remedy
Light will not activate.
• Ensure internal toggle switch is set to the ‘ON position.
• Ensure light is in darkness.
• Wait at least 60 seconds for the program to initialise in darkness.
• Ensure switch setting is on a valid code (See ‘
Flash Codes’
section of
this manual).
• Ensure battery terminals are properly connected.
• Ensure battery voltage is above 3.6volts.
Timing codes will not change.
• Turn rotary switches several times to ensure contacts are clear.
Light will not operate for the
entire night.
• Expose light to direct sunlight and monitor operation for several days.
Avlite products typically require 1.5 hours of direct sunlight per day to
retain full autonomy. From a discharged state, the light may require
several days of operational conditions to ‘cycle’ up to full autonomy.
• Reducing the light output intensity or duty cycle (flash code) will reduce
current draw on the battery.
• Ensure solar module is clean and not covered by shading during the day.
Lights are constantly on
during the day.
• Ensure the flash code is not set to F F. This flash code is for testing
purposes only and will be steady on for 24 hours a day.
Radio controlled models of the AV-OL-70 / AV-OL-70-HI are fitted with a red Status LED. This is found
near the Flash Code Switches. It helps determine a fault with the unit depending on the flash rate of
the Status LED.
Flash Rate
Mode
Status
Condition
On (sec.)
OFF
Steady Off
Off
Normal
Normal running condition in daylight.
1/10
1
On
Normal
Lantern is not synchronised to other lanterns.
1
1
On
Normal
Lantern is synchronised to surrounding lanterns.
Steady On
Off
Flat Battery
Battery is flat.
1/10
1/10
On
Low Battery Battery is low.
1
2/10
On
Factory Set.
Unit is in factory setup mode (FF). Change flash code.