ICAO & FAA Inset Helipad Light 

PREPARATION OF INSTALLATION LOCATION

The AV-HLI2 can be installed in either a 5” (inch), 8” (inch) or direct mounting configuration.
5” Configuration:
For installation in tarmac or concrete helipads it is recommended to use the Avlite AV-MC-58, 5” (inch) 

inset shallow base taking into consideration site specific bearing load, leveling and thermal bonding.
For installations using the 5” inset base configuration, the installation location of each light needs to be 

prepared in accordance with the below mechanical specifications:

8” Configuration:

For installations where there are pre-existing 8” mounting locations or 8” mounting is desired then the 

Avlite AV-MC-55 ,5” to 8”, adaptor ring and AV-MC-54, 8” inset shallow base is required. 
Note: Reuse of the M10x15 screws is not recommended

For installations using the 8” inset base configuration, the installation location of each light needs to 

prepared in accordance with the below mechanical specifications:

Direct Mounting:

For installations where direct mounting of the light fixture to a metal helipad surface is desired, 

the mounting surface of each light must be prepared in accordance with the following mechanical 

specification ensuring the mounting surface is level and has adequate heat dissipation characteristics.

Example Helipad Installation

The recommended mechanical layout for the lighting system on an example helipad is detailed below:

ELECTRICAL INSTALLATION

The procedure for connecting the inset light fixture to the corresponding electrical connections is as 

follows:
• 

Feed input and output cables through corresponding side mounted gland on inset base

• 

Connect each conductor of input cable to separate joint connector (not supplied). One for    

 

+24VDC, one for GND (0VDC) and one for Dim (0-10V) control line.

• 

Connect each conductor of output cable to corresponding joint connector

• 

Connect each conductor of light fly lead to corresponding joint connector as per table 

• 

Tighten each cable gland to ensure sealing

Note:

 Do not cut or modify the fly lead attached to the AV-HLI2 light fixture

Summary of Contents for AV-HLI2

Page 1: ...AV HLI2 ICAO FAA Inset Helipad Light Installation Service Manual Version 1 3...

Page 2: ...Version No Description Date Approved 1 0 Manual launch Dec 2016 W Evans 1 1 General Update Feb 2017 W Evans 1 2 Drawing Update Feb 2017 W Evans...

Page 3: ...elipad Light Table of Contents Introduction Page 4 Technology Page 4 AV HLI2 Models Page 5 Safety Information Page 7 Unpacking installation wiring setup Page 8 Unpacking Page 8 Installation Wiring Pag...

Page 4: ...most remote toughest environments Electronics Avlite employs leading in house electronic engineers in the design and development of software and related circuitry All individual electronic components...

Page 5: ...e level and elevated helipad lighting needs As an alternative to elevated lights Avlite s inset helipad lights are an excellent choice for locations where elevated lights are not suitable or can cause...

Page 6: ...nset Light 5 Inch Inset Light 8 Inch 8 180 A A 275 140 70 SECTION A A CONDUIT PACK TO SUIT TO LIGHT BOX FLUSH WITH CONCRETE B B 273 00 STEEL PIPE 70 140 SECTION B B COAT WITH RELEASE AGENT PACK TO SUI...

Page 7: ...uld only be done by a licensed electrician Operate the light only within the indicated electrical ratings and product usage instructions To ensure that the light and peripheral equipment function safe...

Page 8: ...tments to the unit or wiring with the power on ELECTRICAL INSPECTION AND TEST The inset light is manufactured with a 3 core input fly lead of default length One end of the input cable is molded into t...

Page 9: ...ds to prepared in accordance with the below mechanical specifications Direct Mounting For installations where direct mounting of the light fixture to a metal helipad surface is desired the mounting su...

Page 10: ...rew holes and flange area on the 8 inset base are clean Insert the provided O ring into the O ring groove of the adaptor ring Lower the light fixture onto the inset base ensuring all electrical connec...

Page 11: ...ate Remove light from mount Ensure 24VDC supply source is active Check that 24VDC is present at joint connector feed the light fixture Check polarity of supply line wires is correct Measure voltage of...

Page 12: ...d perimeter lighting Helipad lighting Obstruction lighting For a complete list of product compliances including ICAO FAA please contact Avlite today Helipad Lighting Airfield Markers Accessories A sub...

Reviews: