Step Track Hold Tracking
AvL Technologies
| Proprietary – Content is Subject to Change without Notice
6
3.3.
Signal Configuration Items
Path
Main Window → View
Configuration
Signal
Level 4
Figure 3 - Signal Configuration Window
Long Name
Level
Type
Value Range
Description
Cross Pattern Fine Azimuth
Velocity
4
Float
0.01 – 0.5
Azimuth velocity in degrees/sec for fine peaking
Cross Pattern Fine Elevation
Velocity
4
Float
0.01 – 0.5
Elevation velocity in degrees/sec for fine peaking
Cross Pattern Fine Peaking
Height
4
Float
0.25 – 5
Height in degrees to scan during a fine cross pattern
peaking function
Cross Pattern Fine Peaking
Width
4
Float
0.25 – 5
Width in degrees to scan during a fine cross pattern
peaking function