![AVK 879 Series Installation, Operation & Maintenance Manual Download Page 15](http://html.mh-extra.com/html/avk/879-series/879-series_installation-operation-and-maintenance-manual_3032490015.webp)
PROBLEM
CAUSE
SOLUTION
THE PILOT VALVE
DOES NOT CLOSE TIGHT
Spring
6
is excessively compressed.
Turn the pilot calibration screw
2
counter-clockwise.
Shutter seal gasket
14
is damaged.
Substitute seal gasket
14
.
THE COVER OF THE PILOT
LEAKS
Diaphragm
11
is damaged.
Substitute diaphragm
11
.
ITEM
QTY
DESCRIPTION
MATERIALS
6
1
SPRING
TEMPERED STEEL SiCrV
11
1
DIAPHRAGM
EPDM + NYLON
14
1
SHUTTER
A EPDM
16.2 Pilot: Troubleshooting
16.3 Pilot: Recommended spare parts
ACMO-AVK | IOM Manuals
ACMO-AVK_IOM_879-M100_00-20200520
15
ACMO-AVK CONTROL VALVE SERIES 879
879/BB0X99 - M100 PRESSURE REDUCING VALVE
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.