2.1  Installation guide 

To install this product correctly, please follow the steps below: 

 

1.  Connect the transmitter wires to the flow meter according to the information below. 

NOTE:

 Always consult the manual of the flow meter for correct installation. 

 

VIDI Flow wire definition: 

Wire colour(s) 

Action 

YELLOW or WHITE 

Count (+) 

BLUE 

GND 

RED 

Tamper 

BLACK 

GND 

 

Connect the yellow or white wire to the positive output (+) of the flow meter. 

Connect the blue, red, and black wire together to the flow meter’s GND.  

 

Please look in the VIDI Provisioning Manual for further setup. 

 

2.2  Operation description 

AVK Smart Water’s VIDI products are equipped with a long-lasting non-rechargeable lithium 

battery-powered device that allow the acquisition of physical quantities and sending them using 

low-power radio equipment. 

 

VIDI Flow counts the digital pulses generated by a flow meter when a certain water volume has 

passed through the flow meter. (E.g., every 100 litres).  

 
Transmits the average flow every 30 minutes (LoRa®) or 60 minutes (NB-IoT). In case an alarm 

is detected (tamper or battery alarm), an additional data package is sent immediately. 

 

2.3  Activation/deactivation 

Provisioning and configuration are explained in the VIDI Provisioning Manual. 

 

3.  Maintenance 

3.1  Battery replacement 

The battery replacement can be done by opening the plastic casing by unscrewing the four 

screws in the bottom with a 6mm Torx screwdriver (not included) and removing the lid carefully.  

 

Carefully take out the battery from the casing and disconnect the wire connector attached to the 

Printed Circuit Board (PCB) and replace it with a new battery by connecting the wire connector 

to the PCB. 

 

A new battery can be requested at your local AVK supplier.  

 

 

Once the battery is replaced in the case of the LoRaWAN™ transmitter, the message 

counters are reset to zero. You must then also reset LoRa® server-side. 

 

Summary of Contents for 3001/002

Page 1: ...ch form no 04 186 rev 3 15 Nov 2018 Copyright AVK Holding A S original version rev 8 25 MAY 2022 Installation Operation and Maintenance Manual Version 8 0 VIDI FLOW TRANSMITTER 3001 002 For transmitting water volume to VIDI Cloud ...

Page 2: ...ntent 2 1 Important information before installation 3 1 1 Product information 3 1 2 General warnings and security measures 3 1 3 Manufacturer 3 1 4 Notes 3 1 5 Disposal and recycling 4 1 6 Testing 4 2 Installation and operation 4 2 1 Installation guide 5 2 2 Operation description 5 2 3 Activation deactivation 5 3 Maintenance 5 3 1 Battery replacement 5 ...

Page 3: ... from failure to comply with these instructions Installation must be carried out by personnel who are properly trained to operate on plants where they will be able to install the device Therefore it is absolutely forbidden to install the device if you are unexperienced The device must be installed in sufficiently airy places to prevent any internal overheating Do not place the device in the vicini...

Page 4: ...parate collection and recycling of waste at disposal will help conserve natural resources and ensure environmentally and human friendly recycling For more information about the recycling station closest to your home contact the nearest town hall waste disposal service or the company where the product was purchased Ensure that the rules for the collection of waste and the rules for the correct disp...

Page 5: ... using low power radio equipment VIDI Flow counts the digital pulses generated by a flow meter when a certain water volume has passed through the flow meter E g every 100 litres Transmits the average flow every 30 minutes LoRa or 60 minutes NB IoT In case an alarm is detected tamper or battery alarm an additional data package is sent immediately 2 3 Activation deactivation Provisioning and configu...

Reviews: